# Cangzhou Judun Pipeline Protection Equipment Co., Ltd. (JUDUN / 沧州巨盾管道防护装备有限公司) > ISO 9001, ISO 14001 & ISO 45001 certified direct manufacturer of Pipeline Cathodic Protection (ICCP & Sacrificial Anodes), Solid-State AC/DC Decouplers (SSD), Isolating Spark Gaps (ISG), Polarized Drainage Units, and Permanent Reference Electrodes in Cangzhou, Hebei, China. Compliant with ISO 15589-1:2015, AMPP / NACE SP0169, NACE SP0177, ASTM B843, ASTM B418, and DNV-RP-B401. ## Direct Factory Contact & Verified Corporate Entity - Legal Entity: Cangzhou JUDUN Pipeline Protection Equipment Co., Ltd. (沧州巨盾管道防护装备有限公司 | Brand: JUDUN) - Unified Social Credit Code (Registration): 91130925MA0FK2DU3N (Est. 2020-10-16 | Reg. Capital: RMB 6,780,000 | Grade II Corrosion Contractor Cert: D213450238) - Official Website: https://www.juduncp.com/en (7 Languages: `/en`, `/zh`, `/ru`, `/ar`, `/es`, `/pt`, `/fr`) | HTML Master Index: https://www.juduncp.com/sitemap.html - Overseas Engineering & Sales Email: sales@juduncp.com - Phone / WhatsApp: +86 153 0327 5365 / +86-317-6220889 - Digital Business Card & vCard: https://www.juduncp.com/card | https://www.juduncp.com/judun.vcf - System BoQ Builder & Tender Sheet Upload: https://www.juduncp.com/en/boq - Full Machine-Readable Technical Catalog: https://www.juduncp.com/llms-full.txt ## 5 Flagship Product Lines (5–14 Working Days Ex-Works Lead Time) - [ICCP Transformer-Rectifiers / Potentiostats (KPS Series)](https://www.juduncp.com/en/products/potentiostat): 15V–60V / 10A–200A DC, automatic constant-potential precision <= +/- 5 mV, RS485 Modbus SCADA, 72-hour rated-load burn-in tested. - [Pre-Packaged Shallow, Modular Deep-Well & Flexible MMO Anodes](https://www.juduncp.com/en/products/deep-anode): ASTM B338 Gr.1/2 Titanium with IrO2/Ta2O5 mixed metal oxide coating, calcined petroleum coke canister (< 0.1 Ohm.m), PVDF/HMWPE dual-jacket deep-well cables (15m–150m). - [Solid-State DC Decouplers (SSD / Heavy-Duty Sealed)](https://www.juduncp.com/en/products/ssd): -2.0V / +2.0V DC blocking threshold, 45A–100A rms continuous steady-state AC conduction, >= 3.7 kA AC fault current, 100 kA (8/20 us) surge rating, IP66/IP68 enclosure. - [Arc-Encapsulated Isolating Spark Gaps (JD-ISG-100)](https://www.juduncp.com/en/products/spark): 100 kA (10/350 us Class H) lightning impulse bypass across pipeline insulating joints/flanges, sparkover <= 350–500 V, IP67 sealed chamber. - [Polarized & Smart Stray-Current Drainage Units](https://www.juduncp.com/en/products/polarized-drain): Unidirectional stray DC return for electrified rail / metro crossings. - [Permanent Cu/CuSO4, Ag/AgCl & High-Purity Zn Reference Electrodes](https://www.juduncp.com/en/products/permanent-cse-reference): 20–30 year buried service life, +/- 5 mV potential stability, anti-drying backfill bag. ## Online Engineering Tools & EPC Submittals - [ISO 15589-1 / Dwight / Sunde Online CP Sizing Calculator](https://www.juduncp.com/en/calculator) - [6 Industry Cathodic Protection System Solution Hubs](https://www.juduncp.com/en/solutions) - [International Tender BoQ Specification Cross-Reference Guide](https://www.juduncp.com/en/cross-reference) - [Cathodic Protection Engineering Standards & Parameters Wiki](https://www.juduncp.com/en/wiki) - [EPC CAD Submittal Drawings & Editable Word Tender Spec](https://www.juduncp.com/en/resources) - [Vendor Pre-Qualification (PQQ) & Factory ITP Dossier (PDF)](https://www.juduncp.com/static/downloads/JUDUN_Vendor_PQQ_and_Factory_ITP_Dossier_2026.pdf) - [Field Troubleshooting & Urgent Spare Parts Guide](https://www.juduncp.com/en/troubleshooting) - [6 Typical Pipeline, Storage Tank & Marine CP Reference Configurations](https://www.juduncp.com/en/projects) - [Open-Source Python ISO 15589-1 CP Sizing Package (judun-cp-calc)](https://www.juduncp.com/static/downloads/judun-cp-calc-open-source.zip) - [Global 12-Country Pipeline CP Supply & Shipping Hub](https://www.juduncp.com/en/markets) ## Official Peer-Citable Engineering Literature & Permanent DOIs - CERN Zenodo Official Technical Compendium DOI: https://doi.org/10.5281/zenodo.24520448 - Digital Science Figshare Engineering Dossier DOI: https://doi.org/10.6084/m9.figshare.35114572 - Open Science Framework (OSF) Engineering Registry: https://osf.io/ymf7d/ - Internet Archive Permanent Technical Collection: https://archive.org/details/@judun_cathodic_protection ## 6 Industry Cathodic Protection System Solution Hubs - [Onshore Oil & Gas Transmission Pipeline ICCP & Surge Isolation System (ISO 15589-1 / NACE SP0169)](https://www.juduncp.com/en/solutions/oil-gas-transmission-pipeline-cp) - [Aboveground Storage Tank (AST) Soil-Side Bottom MMO Grid System (API RP 651) (API RP 651 / ISO 15589-1)](https://www.juduncp.com/en/solutions/aboveground-storage-tank-bottom-cp-api-651) - [High-Voltage (110kV–500kV) Shared Corridor Pipeline Induced AC Mitigation System (NACE SP0177 / ISO 18086)](https://www.juduncp.com/en/solutions/hv-power-corridor-pipeline-ac-mitigation) - [Marine Port Steel Piling, LNG Jetty & Subsea Pipeline CP System (DNV-RP-B401) (DNV-RP-B401 / ISO 15589-2)](https://www.juduncp.com/en/solutions/marine-jetty-lng-offshore-subsea-cp) - [Metro & DC Electrified Railway Dynamic Stray-Current Drainage System (EN 50162) (EN 50162 / ISO 15589-1)](https://www.juduncp.com/en/solutions/metro-electrified-rail-stray-current-drainage) - [Desalination Brine, Large Water Mains & PCCP Prestressed Concrete Pipe CP System (AWWA M27 / NACE SP0100)](https://www.juduncp.com/en/solutions/desalination-water-transmission-concrete-pccp-cp) ## 10 International Brand & Tender Specification Equivalent Guides - [SSD / PCR Solid-State DC Decoupler Equivalent (-2V/+2V, 45A–100A AC, 100kA) -> JUDUN SSD-45A / JD-SSD-80/100-SS](https://www.juduncp.com/en/cross-reference/ssd-pcr-solid-state-decoupler-equivalent) - [Kirk Cell (K-5 / K-25 / K-50) Dry Solid-State Decoupler Replacement Guide -> JUDUN SSD-45A / JD-SSD-45/100-HD](https://www.juduncp.com/en/cross-reference/kirk-cell-k5-k25-k50-solid-state-replacement) - [Pipeline Isolating Spark Gap (ISG 100kA 10/350μs, IP67 Sealed) Equivalent Guide -> JUDUN JD-ISG-100](https://www.juduncp.com/en/cross-reference/isolating-spark-gap-exfs-isg-equivalent) - [MMO Tubular, Canister & Ribbon Mesh Anode (LIDA / ELGARD Spec) Equivalent Guide -> JUDUN JD-MMO-25×1000-PKG / MMO Ribbon](https://www.juduncp.com/en/cross-reference/mmo-tubular-canister-anode-lida-elgard-equivalent) - [Modular Pre-Packaged Deep-Well MMO Anode String (15m–150m Borehole) Equivalent -> JUDUN JD-DWA Modular String (15m–150m)](https://www.juduncp.com/en/cross-reference/modular-deep-well-anode-system-matcor-equivalent) - [Continuous Flexible MMO/Ti Linear Anode (Pre-Packed Coke Jacket) Equivalent Guide -> JUDUN JD-FLA-MMO Coke-Jacketed Linear Anode](https://www.juduncp.com/en/cross-reference/flexible-linear-mmo-piggyback-anode-equivalent) - [ICCP Transformer-Rectifier Unit (TRU / Potentiostat 15–60V, 10–200A DC) Equivalent -> JUDUN KPS Air-Cooled / Oil-Immersed / Modular HF](https://www.juduncp.com/en/cross-reference/iccp-transformer-rectifier-potentiostat-equivalent) - [Permanent Buried Reference Electrode (Cu/CuSO4, Ag/AgCl & Zn — 20–30 Yr) Equivalent -> JUDUN CSE-P30 (Cu/CuSO₄) & AGCL-P (Ag/AgCl)](https://www.juduncp.com/en/cross-reference/permanent-reference-electrode-stelth-cse-agcl-equivalent) - [Polarized & Smart DC Stray-Current Drainage Unit (Metro / Electrified Rail) Equivalent -> JUDUN XTDC-30 / JD-PDB-100 & Smart Drain](https://www.juduncp.com/en/cross-reference/polarized-stray-current-drainage-bond-equivalent) - [High-Potential Magnesium (ASTM B843 M1C) & Marine Al-Zn-In (DNV-RP-B401) Equivalent -> JUDUN ASTM B843 HP-Mg (-1.75V) & DNV Al-Zn-In](https://www.juduncp.com/en/cross-reference/sacrificial-mg-al-zn-anode-astm-dnv-equivalent) --- ## 6 Complete Industry System Architectures & Direct Factory BOMs ### Onshore Oil & Gas Transmission Pipeline ICCP & Surge Isolation System (ISO 15589-1 / NACE SP0169) - URL: https://www.juduncp.com/en/solutions/oil-gas-transmission-pipeline-cp | ZH: https://www.juduncp.com/zh/solutions/oil-gas-transmission-pipeline-cp | RU: https://www.juduncp.com/ru/solutions/oil-gas-transmission-pipeline-cp | AR: https://www.juduncp.com/ar/solutions/oil-gas-transmission-pipeline-cp - Engineering Summary: Long-distance 3LPE/FBE-coated steel transmission pipelines achieve uniform -850 mV to -1200 mV CSE instant-off polarization using automatic KPS transformer-rectifiers spaced every 25–50 km, paired with shallow canister or 15–150m deep-well MMO groundbeds, buried CSE-P30 reference cells, and 100kA isolating spark gaps across station insulating joints. - DC Power Supply / 恒电位直流电源: `KPS-50V/30A ~ 60V/100A` (≤ ±5 mV Auto-Potential, RS485 Modbus, 72h Burn-In) -> https://www.juduncp.com/en/products/potentiostat - Deep Borehole Groundbed / 深井阳极地床: `JD-DWA Modular MMO String` (15m–150m Borehole, PVDF/HMWPE Chlorine-Proof Cable) -> https://www.juduncp.com/en/products/deep-anode - Shallow Canister Bed / 浅埋预包装阳极: `JD-MMO-25×1000-PKG` (ASTM B338 Ti IrO₂/Ta₂O₅ in <0.1 Ω·m Calcined Coke) -> https://www.juduncp.com/en/products/shallow-anode - Station IJ Surge Bypass / 绝缘接头防雷: `JD-ISG-100 Spark Gap` (100 kA (10/350μs Class H), ≥100 MΩ DC Isolation, IP67) -> https://www.juduncp.com/en/products/spark - Closed-Loop Sensing / 闭环电位监测: `CSE-P30 + Smart Test Post` (20–30 Yr Gelled Cu/CuSO₄ (±5 mV) + IR-Free Coupon) -> https://www.juduncp.com/en/products/permanent-cse-reference ### Aboveground Storage Tank (AST) Soil-Side Bottom MMO Grid System (API RP 651) (API RP 651 / ISO 15589-1) - URL: https://www.juduncp.com/en/solutions/aboveground-storage-tank-bottom-cp-api-651 | ZH: https://www.juduncp.com/zh/solutions/aboveground-storage-tank-bottom-cp-api-651 | RU: https://www.juduncp.com/ru/solutions/aboveground-storage-tank-bottom-cp-api-651 | AR: https://www.juduncp.com/ar/solutions/aboveground-storage-tank-bottom-cp-api-651 - Engineering Summary: Between the HDPE secondary containment geomembrane and steel tank floor, a concentric MMO titanium ribbon mesh grid (spot-welded at 90° to titanium conductor bars) or continuous coke-jacketed flexible MMO anode delivers uniform current density across large-diameter AST bottoms without high-voltage edge over-polarization. - Tank-Bottom Grid / 罐底网状阳极带: `MMO Ribbon 6.35×0.635mm + Ti Bar` (ASTM B265 Gr.1 Ti, NACE TM0108 50-Yr Grid Life) -> https://www.juduncp.com/en/products/mmo-ribbon-anode - Retrofit / Ring Option / 连续柔性阳极: `JD-FLA-MMO Coke-Jacketed Reel` (Uniform Perimeter / Under-Floor Linear Output) -> https://www.juduncp.com/en/products/flexible-anode - Zone Power Supply / 恒电位整流机: `KPS-15V/50A ~ 30V/100A` (Low-Voltage High-Current Ripple-Filtered Output) -> https://www.juduncp.com/en/products/potentiostat - Under-Center Sensing / 罐底双冗余参比: `CSE-P30 + High-Purity Zn Pair` (Perforated Slotted Monitoring Tube Ready) -> https://www.juduncp.com/en/products/permanent-cse-reference - Zone Shunt Balancing / 多回路分流箱: `JD-AJB-SS316L Multi-Shunt` (0.01Ω Precision Shunts per Tank Quadrant) -> https://www.juduncp.com/en/products/anode-junction ### High-Voltage (110kV–500kV) Shared Corridor Pipeline Induced AC Mitigation System (NACE SP0177 / ISO 18086) - URL: https://www.juduncp.com/en/solutions/hv-power-corridor-pipeline-ac-mitigation | ZH: https://www.juduncp.com/zh/solutions/hv-power-corridor-pipeline-ac-mitigation | RU: https://www.juduncp.com/ru/solutions/hv-power-corridor-pipeline-ac-mitigation | AR: https://www.juduncp.com/ar/solutions/hv-power-corridor-pipeline-ac-mitigation - Engineering Summary: Where buried steel pipelines share right-of-way with 110kV–500kV overhead HVAC transmission lines, Solid-State DC Decouplers (SSD-45A / MSSD-100) bonded to continuous ASTM B418 zinc ribbon grounding mats clamp steady-state touch voltage below 15V AC (NACE SP0177) and AC current density below 20 A/m² (ISO 18086) without losing CP polarization. - Standard Corridor Decoupler / 标准固态去耦合器: `SSD-45A (-2V/+2V, 45A AC)` (3.7kA Fault, 100kA (8/20μs) Surge, <100 μA DC Leakage) -> https://www.juduncp.com/en/products/ssd - 330–500kV Heavy Decoupler / 大通流密封去耦合器: `MSSD-80/100 (IP68 Sealed)` (80A–100A Continuous AC, 5.0kA Fault, 316L/Die-Cast) -> https://www.juduncp.com/en/products/ex-ssd - Low-Impedance AC Earth / 排流接地极: `ASTM B418 Diamond Zinc Ribbon` (Continuous Trench Grounding Mat w/ Steel Core) -> https://www.juduncp.com/en/products/zinc-ribbon - AC Density Verification / 交流电流密度监测: `1 cm² / 10 cm² AC/DC Coupon` (ISO 18086 J_AC & Instant-Off Verification) -> https://www.juduncp.com/en/products/coupon ### Marine Port Steel Piling, LNG Jetty & Subsea Pipeline CP System (DNV-RP-B401) (DNV-RP-B401 / ISO 15589-2) - URL: https://www.juduncp.com/en/solutions/marine-jetty-lng-offshore-subsea-cp | ZH: https://www.juduncp.com/zh/solutions/marine-jetty-lng-offshore-subsea-cp | RU: https://www.juduncp.com/ru/solutions/marine-jetty-lng-offshore-subsea-cp | AR: https://www.juduncp.com/ar/solutions/marine-jetty-lng-offshore-subsea-cp - Engineering Summary: Submerged steel tubular piles, sheet-pile quay walls, seawater intake caissons, and offshore subsea pipelines achieve 20–30 year corrosion protection in high-chloride seawater using DNV-RP-B401 Al-Zn-In structural/bracelet anodes (≥2400 Ah/kg) or marine MMO sleds monitored by chloride-immune sintered Ag/AgCl reference cells. - Structural / Bracelet Anode / 海工铝阳极: `DNV-RP-B401 Al-Zn-In Series` (≥2400 Ah/kg, -1.05V vs Ag/AgCl, OES Heat Tested) -> https://www.juduncp.com/en/products/aluminum-anode - Ballast & Brackish Water / 海工高纯锌阳极: `ASTM B418 Type I Low-Iron Zn` (Fe ≤0.0014%, Reliable Activation in Mud/Estuary) -> https://www.juduncp.com/en/products/zinc-anode - Marine Reference Cell / 海水银氯化银参比: `AGCL-P Sintered Ag/AgCl` (+0.250V ±5 mV vs SHE, Immune to Seawater Cl⁻) -> https://www.juduncp.com/en/products/silver-chloride-reference - Jetty ICCP Option / 码头外加电流整流机: `KPS Marine IP65 Oil-Cooled TRU` (Salt-Fog Resistant Cabinet w/ RS485 SCADA) -> https://www.juduncp.com/en/products/potentiostat ### Metro & DC Electrified Railway Dynamic Stray-Current Drainage System (EN 50162) (EN 50162 / ISO 15589-1) - URL: https://www.juduncp.com/en/solutions/metro-electrified-rail-stray-current-drainage | ZH: https://www.juduncp.com/zh/solutions/metro-electrified-rail-stray-current-drainage | RU: https://www.juduncp.com/ru/solutions/metro-electrified-rail-stray-current-drainage | AR: https://www.juduncp.com/ar/solutions/metro-electrified-rail-stray-current-drainage - Engineering Summary: DC traction return rails inject fluctuating stray currents into nearby gas and water mains, causing rapid localized anodic wall perforation at current discharge zones. Unidirectional Polarized Drainage Units (XTDC) and Potential-Gated Smart Drains return stray current directly to the traction negative bus while blocking reverse injection. - Unidirectional Bond / 单向极性排流器: `XTDC-30 / JD-PDB-100` (Turn-On ≤0.35–0.40V, Reverse Blocking ≥1200V) -> https://www.juduncp.com/en/products/polarized-drain - Potential-Gated Control / 智能受控排流器: `JD-SDU Smart Drainage Cabinet` (Prevents Over-Polarization + RS485 Data Logging) -> https://www.juduncp.com/en/products/smart-drain - Sectional Isolation / 分段绝缘防雷: `JD-ISG-100 Spark Gap` (Protects City Gate Station Insulating Flanges) -> https://www.juduncp.com/en/products/spark - 24h Swing Recording / 远程电位监测: `IoT Smart Potential Test Station` (Tracks Peak Positive/Negative Potential Shifts) -> https://www.juduncp.com/en/products/smart-test-post ### Desalination Brine, Large Water Mains & PCCP Prestressed Concrete Pipe CP System (AWWA M27 / NACE SP0100) - URL: https://www.juduncp.com/en/solutions/desalination-water-transmission-concrete-pccp-cp | ZH: https://www.juduncp.com/zh/solutions/desalination-water-transmission-concrete-pccp-cp | RU: https://www.juduncp.com/ru/solutions/desalination-water-transmission-concrete-pccp-cp | AR: https://www.juduncp.com/ar/solutions/desalination-water-transmission-concrete-pccp-cp - Engineering Summary: Large-diameter steel water pipelines and Prestressed Concrete Cylinder Pipes (PCCP) require controlled polarization that prevents corrosion without exceeding hydrogen-embrittlement limits (-950 mV to -1000 mV CSE on high-strength prestressing wire per NACE SP0100), achieved via zinc ribbon anodes or current-limited linear MMO systems. - Hydrogen-Safe PCCP Anode / 防氢脆连续锌带: `ASTM B418 Zinc Ribbon Anode` (Self-Regulating -1.10V CSE Ceiling for PCCP Wire) -> https://www.juduncp.com/en/products/zinc-ribbon - High-Resistivity Trench / 高电位预包装镁阳极: `ASTM B843 M1C Pre-Packaged Mg` (-1.75V Driving Potential for Cement/Epoxy Steel Pipe) -> https://www.juduncp.com/en/products/magnesium-anode - Sabkha / Concrete Sensing / 混凝土与盐渍土参比: `AGCL-P & CSE-P30 Reference Cells` (20–30 Yr Embeddable Potential Verification) -> https://www.juduncp.com/en/products/silver-chloride-reference - Continuity Bonding / 跨接铝热焊与补口: `CP Exothermic Weld + Viscoelastic` (Low-Resistance Joint Continuity Bonding) -> https://www.juduncp.com/en/products/weld-metal --- ## Complete 39-Product Technical Catalog (JUDUN) ### ICCP Transformer-Rectifier & Cathodic Protection Potentiostat (阴极保护恒电位仪(外加电流智能整流电源 KPS)) - URL: https://www.juduncp.com/en/products/potentiostat | RU: https://www.juduncp.com/ru/products/potentiostat | AR: https://www.juduncp.com/ar/products/potentiostat - Standard Models: KPS-30V/20A, KPS-50V/30A, KPS-50V/50A-D, KPS-60V/100A - Standards: ISO 15589-1, NACE SP0169, GB/T 21448, SY/T 0036 - Summary: Precision transformer-rectifier / potentiostat for impressed current cathodic protection (ICCP), featuring automatic potential/current control, surge protection, and RS485 Modbus telemetry. ### Solid-State DC Decoupler (SSD) for Pipeline AC Mitigation (固态去耦合器(管道隔直通交排流器 SSD)) - URL: https://www.juduncp.com/en/products/ssd | RU: https://www.juduncp.com/ru/products/ssd | AR: https://www.juduncp.com/ar/products/ssd - Standard Models: SSD-50-100-B302015, SSD-50-100-B403015, MSSD-50/100 - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Blocks cathodic protection DC current while providing a low-impedance path to ground for induced steady-state AC current, AC fault surges, and lightning transients. ### Isolating Spark Gap (Arc-Encapsulated ISG) Surge Arrester (电火花间隙(密封型绝缘接头保护器 ISG)) - URL: https://www.juduncp.com/en/products/spark | RU: https://www.juduncp.com/ru/products/spark | AR: https://www.juduncp.com/ar/products/spark - Standard Models: JD-ISG-50, JD-ISG-100 - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Installed across pipeline insulating joints/flanges to maintain open-circuit DC/AC isolation under normal operation while firing instantaneously inside a sealed arc chamber during lightning or HV surge events. ### Polarized Stray Current Drainage Bond (Unidirectional Diode XTDC) (极性排流器(单向直流杂散电流排流器 XTDC)) - URL: https://www.juduncp.com/en/products/polarized-drain | RU: https://www.juduncp.com/ru/products/polarized-drain | AR: https://www.juduncp.com/ar/products/polarized-drain - Standard Models: XTDC-10/30, JD-PDB-50, JD-PDB-100 - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Low-forward-drop solid-state diode drainage bond allowing stray DC current to return unidirectionally from the pipeline to traction negative rails or grounding beds while blocking reverse current injection. ### Permanent Cu/CuSO4 Reference Electrode (Long-Life Buried CSE) (永久性硫酸铜参比电极(长效埋地型 Cu/CuSO4 参比电极)) - URL: https://www.juduncp.com/en/products/permanent-cse-reference | RU: https://www.juduncp.com/ru/products/permanent-cse-reference | AR: https://www.juduncp.com/ar/products/permanent-cse-reference - Standard Models: CSE-P15, CSE-P30 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Controlled-porosity ceramic membrane with gelled saturated CuSO₄ electrolyte and moisture-retentive backfill, engineered to resist drying out in onshore soil and tank-bottom service. ### Pre-Packaged Shallow Groundbed Anode (MMO Tubular & HSCI) (浅埋式辅助阳极(预包装高硅铸铁 / MMO 贵金属管状阳极)) - URL: https://www.juduncp.com/en/products/shallow-anode | RU: https://www.juduncp.com/ru/products/shallow-anode | AR: https://www.juduncp.com/ar/products/shallow-anode - Standard Models: JD-MMO-25×1000-C, JD-MMO-32×1200-C, JD-HSCI-75×1500 - Standards: ISO 15589-1, NACE SP0169, GB/T 21448, SY/T 0036 - Summary: Pre-packaged canister MMO tubular or high-silicon cast iron (HSCI) anode with metallurgical coke breeze backfill for low-resistance horizontal or vertical shallow groundbeds. ### Modular Deep-Well Impressed Current Anode System (ICCP) (深井用辅助阳极(外加电流成套深井阳极体 MMO / 高硅铸铁)) - URL: https://www.juduncp.com/en/products/deep-anode | RU: https://www.juduncp.com/ru/products/deep-anode | AR: https://www.juduncp.com/ar/products/deep-anode - Standard Models: JD-DW-MMO-30A, JD-DW-MMO-50A - Standards: ISO 15589-1, NACE SP0169, GB/T 21448, SY/T 0036 - Summary: Factory-assembled modular deep-well anode string (15m–150m depth) offering minimal right-of-way footprint, wide current spread, and low stray interference to foreign structures. ### MMO/Ti Flexible Linear Anode for Tank Bottoms & Station Piping (柔性阳极(MMO/Ti 储罐底板与站场连续线性阳极)) - URL: https://www.juduncp.com/en/products/flexible-anode | RU: https://www.juduncp.com/ru/products/flexible-anode | AR: https://www.juduncp.com/ar/products/flexible-anode - Standard Models: MMO/Ti-Flex-1.5/10, MMO/Ti-Flex-2.0/16 - Standards: ISO 15589-1, NACE SP0169, GB/T 21448, SY/T 0036 - Summary: Continuous linear MMO/Ti wire or conductive polymer flexible anode pre-packed with coke breeze fabric jacket for uniform current distribution on storage tank bottoms and congested station piping. ### Heavy-Duty Sealed Solid-State Decoupler (SSD-HD) (重载密封型固态去耦合器) - URL: https://www.juduncp.com/en/products/ex-ssd | RU: https://www.juduncp.com/ru/products/ex-ssd | AR: https://www.juduncp.com/ar/products/ex-ssd - Standard Models: JD-SSD-45/100-HD, JD-SSD-80/100-SS - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Heavy-duty sealed solid-state decoupler housed in copper-free cast aluminum or 316L stainless steel (IP66/IP68) for gas stations, valve chambers, tank farms, and insulating joints; custom hazardous-area housing available per project specification. ### Intelligent Stray Current Drainage Unit (智能排流器) - URL: https://www.juduncp.com/en/products/smart-drain | RU: https://www.juduncp.com/ru/products/smart-drain | AR: https://www.juduncp.com/ar/products/smart-drain - Standard Models: JD-SDR-50A, JD-SDR-100A - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Microprocessor-controlled active/passive stray current drainage station for metro rail, HVDC ground electrodes, and dynamic traction interference corridors with telemetry logging. ### Magnesium Alloy Sacrificial Anode (镁合金牺牲阳极) - URL: https://www.juduncp.com/en/products/magnesium | RU: https://www.juduncp.com/ru/products/magnesium | AR: https://www.juduncp.com/ar/products/magnesium - Standard Models: MG-8kg-P, MG-14kg-P, MG-22kg-P - Standards: ASTM B843, ASTM B418, ISO 15589-1, GB/T 17731, GB/T 4950 - Summary: Available in High-Potential (M1C, -1.75V CSE) and Standard-Potential (AZ63B, -1.50V CSE) alloys, supplied bare or pre-packaged in gypsum-bentonite cotton bags with pre-welded lead wires. ### Zinc Alloy Sacrificial Anode (锌合金牺牲阳极) - URL: https://www.juduncp.com/en/products/zinc-anode | RU: https://www.juduncp.com/ru/products/zinc-anode | AR: https://www.juduncp.com/ar/products/zinc-anode - Standard Models: ZN-11kg, ZN-23kg, ZN-35kg - Standards: ASTM B843, ASTM B418, ISO 15589-1, GB/T 17731, GB/T 4950 - Summary: High-purity Zn-Al-Cd / MIL-A-18001K / ASTM B418 zinc sacrificial anodes offering >90% current efficiency with zero over-protection risk for marine structures, ballast/crude storage tanks, and low-resistivity soils. ### Zinc Ribbon Anode (锌带阳极) - URL: https://www.juduncp.com/en/products/zinc-ribbon | RU: https://www.juduncp.com/ru/products/zinc-ribbon | AR: https://www.juduncp.com/ar/products/zinc-ribbon - Standard Models: JRS-3/4×5/8 (Standard), JR-1/2×9/16 (Regular), JR-Super-1×1-1/4 - Standards: ASTM B843, ASTM B418, ISO 15589-1, GB/T 17731, GB/T 4950 - Summary: Extruded diamond-profile high-purity zinc ribbon with centralized steel wire core (ASTM B418 Type II), widely deployed alongside solid-state decouplers for AC mitigation grounding mats and cased pipeline crossings. ### Indirect Equipotential Bonding Device (等电位连接器) - URL: https://www.juduncp.com/en/products/equipotential | RU: https://www.juduncp.com/ru/products/equipotential | AR: https://www.juduncp.com/ar/products/equipotential - Standard Models: JD-EQB-60, JD-EQB-100 - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Provides indirect equipotential bonding between cathodically protected piping and station earthing grids—isolated during normal operation and instantaneously clamped under overvoltage faults. ### Zinc Grounding Cell (锌接地电池) - URL: https://www.juduncp.com/en/products/zinc-grounding-cell | RU: https://www.juduncp.com/ru/products/zinc-grounding-cell | AR: https://www.juduncp.com/ar/products/zinc-grounding-cell - Standard Models: ZGC-2×12, ZGC-4×12 - Standards: NACE SP0177, ISO 18086, EN 50162, UL94 V-0-1 (Ex), GB/T 50698 - Summary: Dual/quad high-purity zinc electrodes separated by insulating spacers inside a low-resistivity backfill bag—buried across insulating joints or AC grounding grids for passive surge and AC drainage. ### Cathodic Protection Test Station (阴极保护测试桩) - URL: https://www.juduncp.com/en/products/test-post | RU: https://www.juduncp.com/ru/products/test-post | AR: https://www.juduncp.com/ar/products/test-post - Standard Models: JD-TP-SS304-6T, JD-TP-FRP-8T, JD-TP-CS-10T - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Right-of-way pipeline monitoring post for potential measurement, sacrificial anode current testing, casing isolation checks, and coupon connections. Available in 304/316L stainless steel, coated carbon steel, or UV-stabilized FRP. ### Station Heavy-Duty Terminal Test Post (场站重型接线箱测试桩) - URL: https://www.juduncp.com/en/products/ex-test-post | RU: https://www.juduncp.com/ru/products/ex-test-post | AR: https://www.juduncp.com/ar/products/ex-test-post - Standard Models: JD-STP-8, JD-STP-12-SS - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Station-grade cathodic protection test station featuring an IP65/IP66 sealed cast-aluminum or 316L stainless terminal head for refineries, gas compressor stations, tank farms, and LNG terminals (custom hazardous-area spec optional). ### Permanent Reference Electrode (长效参比电极) - URL: https://www.juduncp.com/en/products/permanent-reference | RU: https://www.juduncp.com/ru/products/permanent-reference | AR: https://www.juduncp.com/ar/products/permanent-reference - Standard Models: JD-PRE-CSE-20, JD-PRE-DUAL - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Buried long-life electrochemical reference sensor providing drift-free potential feedback for automatic ICCP transformer-rectifiers and remote monitoring data loggers. ### Silver/Silver Chloride Reference Electrode (Ag/AgCl) (银/氯化银参比电极 (Ag/AgCl)) - URL: https://www.juduncp.com/en/products/silver-chloride-reference | RU: https://www.juduncp.com/ru/products/silver-chloride-reference | AR: https://www.juduncp.com/ar/products/silver-chloride-reference - Standard Models: AGCL-P (Perforated Marine/Soil), AGCL-PG (Pre-Gelled Soil/Concrete) - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: High-stability sintered Ag/AgCl reference electrode built for seawater, brackish mud, high-chloride saline soils, and reinforced concrete structures where CSE electrodes suffer chloride contamination. ### Permanent High-Purity Zinc Reference Electrode (长效高纯锌参比电极) - URL: https://www.juduncp.com/en/products/high-purity-zinc-reference | RU: https://www.juduncp.com/ru/products/high-purity-zinc-reference | AR: https://www.juduncp.com/ar/products/high-purity-zinc-reference - Standard Models: ZRE-Soil-P, ZRE-Marine-B - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Cast from ≥99.995% ultra-pure zinc (ASTM B418 Type II); immune to freezing or electrolyte drying, widely paired with CSE or Ag/AgCl as a rugged secondary/redundant reference in tank bottoms and marine service. ### Portable Reference Electrode (便携式参比电极) - URL: https://www.juduncp.com/en/products/reference | RU: https://www.juduncp.com/ru/products/reference | AR: https://www.juduncp.com/ar/products/reference - Standard Models: JD-CSE-Port-30, JD-CSE-Stick-900 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Field-refillable transparent acrylic tube portable Cu/CuSO₄ electrode with replaceable porous ceramic tip and pure copper rod for routine test-post surveys and CIPS/DCVG inspections. ### Reference Electrode Access Tube (参比管) - URL: https://www.juduncp.com/en/products/reference-tube | RU: https://www.juduncp.com/ru/products/reference-tube | AR: https://www.juduncp.com/ar/products/reference-tube - Standard Models: JD-RT-DN65, JD-RT-Paved - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Slotted/porous access conduit pre-installed beneath storage tank bottoms or paved surfaces, allowing operators to insert or replace reference sensors from the tank perimeter to verify center-bottom potentials. ### Polarization Coupon (极化试片) - URL: https://www.juduncp.com/en/products/coupon | RU: https://www.juduncp.com/ru/products/coupon | AR: https://www.juduncp.com/ar/products/coupon - Standard Models: JD-PC-1cm2, JD-PC-10cm2 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Pipeline-grade steel coupon (20#, L245, X65, X70, X80) with calibrated exposed surface area (1 cm² / 6.5 cm² / 10 cm²) for accurate IR-free instant-off potential and AC/DC current density monitoring. ### Native Coupon (Free-Corroding Coupon) (自然试片) - URL: https://www.juduncp.com/en/products/natural-coupon | RU: https://www.juduncp.com/ru/products/natural-coupon | AR: https://www.juduncp.com/ar/products/natural-coupon - Standard Models: JD-NC-10 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Electrically isolated coupon buried in the same trench soil as the pipeline to establish baseline native corrosion potential for verifying the NACE 100 mV polarization decay/formation criterion. ### Corrosion Inspection Coupon (Weight-Loss) (检查片) - URL: https://www.juduncp.com/en/products/inspection-coupon | RU: https://www.juduncp.com/ru/products/inspection-coupon | AR: https://www.juduncp.com/ar/products/inspection-coupon - Standard Models: JD-WL-Set6 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Pre-weighed, serialized paired weight-loss coupons (cathodically bonded vs. unbonded control) per SY/T 0029 & ASTM G1 for quantitative corrosion rate (mm/yr) and CP protection efficiency evaluation. ### Polarization Probe (Integrated Coupon + Reference) (极化探头) - URL: https://www.juduncp.com/en/products/probe | RU: https://www.juduncp.com/ru/products/probe | AR: https://www.juduncp.com/ar/products/probe - Standard Models: JD-PP-65, JD-PP-AC1 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Combines a permanent Cu/CuSO₄ reference cell and a pipeline-matched steel polarization coupon with an internal Luggin capillary tip right at the steel surface to eliminate soil IR-drop error. ### Cathodic Protection Potential Data Logger (智能电位采集仪) - URL: https://www.juduncp.com/en/products/collector | RU: https://www.juduncp.com/ru/products/collector | AR: https://www.juduncp.com/ar/products/collector - Standard Models: JD-DL-4G-IP68, JD-DL-AL-IP68 - Standards: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246 - Summary: Ultra-low-power 4G / LTE Cat-M1 / NB-IoT wireless telemetry logger that fits directly inside standard or station CP test posts to measure ON/OFF potentials, AC voltage, and coupon currents. ### Insulating Joint Protector Junction Box (绝缘接头保护器接线箱) - URL: https://www.juduncp.com/en/products/junction | RU: https://www.juduncp.com/ru/products/junction | AR: https://www.juduncp.com/ar/products/junction - Standard Models: JD-IJB-ISG, JD-IJB-SSD-HD - Standards: IEC 60529 (IP65/IP66), ISO 15589-1, SY/T 0096 - Summary: Weatherproof IP65/IP66 outdoor enclosure integrating an isolating spark gap or SSD, heavy copper busbars, and test terminals for buried pipeline insulating joint protection and routine testing. ### Anode Junction Box (阳极接线箱) - URL: https://www.juduncp.com/en/products/anode-junction | RU: https://www.juduncp.com/ru/products/anode-junction | AR: https://www.juduncp.com/ar/products/anode-junction - Standard Models: JD-AJB-6W, JD-AJB-12W-SS - Standards: IEC 60529 (IP65/IP66), ISO 15589-1, SY/T 0096 - Summary: Centralizes multiple shallow or deep-well ICCP anode leads onto a common positive busbar, equipped with individual precision manganin shunts and adjustable wire-wound balancing resistors per circuit. ### Cathode Bonding & Junction Box (阴极接线箱) - URL: https://www.juduncp.com/en/products/cathode-junction | RU: https://www.juduncp.com/ru/products/cathode-junction | AR: https://www.juduncp.com/ar/products/cathode-junction - Standard Models: JD-CJB-4W, JD-CJB-8W-R - Standards: IEC 60529 (IP65/IP66), ISO 15589-1, SY/T 0096 - Summary: Provides controlled negative return distribution and interference-mitigation bonding across parallel pipelines, station headers, and multi-structure tank farms via shunts, blocking diodes, and variable resistors. ### Weld-Free Cable-to-Pipe Connector (免焊接头) - URL: https://www.juduncp.com/en/products/weld-free-connector | RU: https://www.juduncp.com/ru/products/weld-free-connector | AR: https://www.juduncp.com/ar/products/weld-free-connector - Standard Models: JD-WFC-16, JD-WFC-35 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Cold-applied mechanical & conductive-adhesive cable connection assembly requiring zero open flame or heat—ideal for live in-service oil & gas pipelines and hazardous zones where hot work is prohibited. ### Exothermic Weld Metal (CP Pipe Formulation) (铝热焊剂) - URL: https://www.juduncp.com/en/products/weld-metal | RU: https://www.juduncp.com/ru/products/weld-metal | AR: https://www.juduncp.com/ar/products/weld-metal - Standard Models: JD-EWM-15, JD-EWM-32, JD-EWM-45 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Controlled-heat copper-oxide exothermic welding powder formulated specifically for steel pipelines (low penetration depth per NACE/ISO guidelines), creating a permanent molecular metallurgical bond. ### Exothermic Welding Graphite Mold (焊接模具) - URL: https://www.juduncp.com/en/products/weld-mould | RU: https://www.juduncp.com/ru/products/weld-mould | AR: https://www.juduncp.com/ar/products/weld-mould - Standard Models: JD-GM-H16, JD-GM-V25 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Precision CNC-machined high-density refractory graphite molds contoured to match exact pipe outside diameters (horizontal or vertical pipe-wall orientation), rated for 50–80+ exothermic welds per mold. ### Exothermic Welding Flint Igniter & Tool Kit (点火枪) - URL: https://www.juduncp.com/en/products/weld-tools | RU: https://www.juduncp.com/ru/products/weld-tools | AR: https://www.juduncp.com/ar/products/weld-tools - Standard Models: JD-IGN-01, JD-EWTK-Full - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Heavy-duty spring-loaded flint spark igniter gun paired with mold cleaning brushes, slag scrapers, and locking pliers for safe, reliable exothermic weld ignition in the field. ### Pipeline Coating Repair Patch & Weld Cap (补伤片) - URL: https://www.juduncp.com/en/products/weld-corrosion | RU: https://www.juduncp.com/ru/products/weld-corrosion | AR: https://www.juduncp.com/ar/products/weld-corrosion - Standard Models: JD-RP-150×150, JD-WC-100 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Radiation cross-linked polyethylene (3PE compatible) heat-shrinkable repair patches and mastic-filled weld-point handy caps for sealing exothermic cable welds and holiday defects. ### Pipeline Coating Melt Repair Stick (补伤棒) - URL: https://www.juduncp.com/en/products/repair-stick | RU: https://www.juduncp.com/ru/products/repair-stick | AR: https://www.juduncp.com/ar/products/repair-stick - Standard Models: JD-RS-25×250 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Solvent-free solid heat-melt copolymer adhesive repair stick for rapid field filling of pinholes, gouges, and holidays (≤ 30 mm) on 2PE / 3PE coated steel pipes prior to patch application. ### Viscoelastic Corrosion Protection Paste (粘弹体膏) - URL: https://www.juduncp.com/en/products/viscoelastic-paste | RU: https://www.juduncp.com/ru/products/viscoelastic-paste | AR: https://www.juduncp.com/ar/products/viscoelastic-paste - Standard Models: JD-VEP-2kg - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Non-curing polyisobutylene viscoelastic molding paste requiring minimal surface preparation (St2 wire brush), cold-flowing into flange bolts, valve bodies, insulating joints, and cable welds to displace moisture. ### Viscoelastic Corrosion Protection Tape (粘弹体胶带) - URL: https://www.juduncp.com/en/products/anticorrosion-tape | RU: https://www.juduncp.com/ru/products/anticorrosion-tape | AR: https://www.juduncp.com/ar/products/anticorrosion-tape - Standard Models: JD-VET-100×10, JD-VET-50×10 - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: ISO 21809-3 compliant cold-applied viscoelastic wrap tape with PE backing film—paired with PVC/PE outer mechanical wrap for long-life corrosion sealing of field joints, risers, elbows, and flanges. ### Cable Conduit Moisture & Firestop Sealing Compound (穿线管防渗阻燃密封胶泥) - URL: https://www.juduncp.com/en/products/cable-sealing | RU: https://www.juduncp.com/ru/products/cable-sealing | AR: https://www.juduncp.com/ar/products/cable-sealing - Standard Models: JD-CSM-1kg, JD-FSP-1kg - Standards: ISO 21809-3, NACE SP0169, SY/T 0413, UL94 V-0 - Summary: Halogen-free flame-retardant sealing putty for gas-tight, moisture-blocking, and firestop sealing of cable conduits entering CP test stations, junction boxes, and rectifier cabinets. --- ## International Tender Specification Cross-Reference Table & Dedicated Equivalent Guides - **SSD / PCR Solid-State DC Decoupler Equivalent (-2V/+2V, 45A–100A AC, 100kA)** -> JUDUN `SSD-45A / JD-SSD-80/100-SS` (5–7 Working Days) -> https://www.juduncp.com/en/cross-reference/ssd-pcr-solid-state-decoupler-equivalent - **Kirk Cell (K-5 / K-25 / K-50) Dry Solid-State Decoupler Replacement Guide** -> JUDUN `SSD-45A / JD-SSD-45/100-HD` (5–7 Working Days) -> https://www.juduncp.com/en/cross-reference/kirk-cell-k5-k25-k50-solid-state-replacement - **Pipeline Isolating Spark Gap (ISG 100kA 10/350μs, IP67 Sealed) Equivalent Guide** -> JUDUN `JD-ISG-100` (3–7 Working Days) -> https://www.juduncp.com/en/cross-reference/isolating-spark-gap-exfs-isg-equivalent - **MMO Tubular, Canister & Ribbon Mesh Anode (LIDA / ELGARD Spec) Equivalent Guide** -> JUDUN `JD-MMO-25×1000-PKG / MMO Ribbon` (5–10 Working Days) -> https://www.juduncp.com/en/cross-reference/mmo-tubular-canister-anode-lida-elgard-equivalent - **Modular Pre-Packaged Deep-Well MMO Anode String (15m–150m Borehole) Equivalent** -> JUDUN `JD-DWA Modular String (15m–150m)` (7–12 Working Days) -> https://www.juduncp.com/en/cross-reference/modular-deep-well-anode-system-matcor-equivalent - **Continuous Flexible MMO/Ti Linear Anode (Pre-Packed Coke Jacket) Equivalent Guide** -> JUDUN `JD-FLA-MMO Coke-Jacketed Linear Anode` (7–12 Working Days) -> https://www.juduncp.com/en/cross-reference/flexible-linear-mmo-piggyback-anode-equivalent - **ICCP Transformer-Rectifier Unit (TRU / Potentiostat 15–60V, 10–200A DC) Equivalent** -> JUDUN `KPS Air-Cooled / Oil-Immersed / Modular HF` (7–14 Working Days) -> https://www.juduncp.com/en/cross-reference/iccp-transformer-rectifier-potentiostat-equivalent - **Permanent Buried Reference Electrode (Cu/CuSO4, Ag/AgCl & Zn — 20–30 Yr) Equivalent** -> JUDUN `CSE-P30 (Cu/CuSO₄) & AGCL-P (Ag/AgCl)` (3–5 Working Days) -> https://www.juduncp.com/en/cross-reference/permanent-reference-electrode-stelth-cse-agcl-equivalent - **Polarized & Smart DC Stray-Current Drainage Unit (Metro / Electrified Rail) Equivalent** -> JUDUN `XTDC-30 / JD-PDB-100 & Smart Drain` (5–7 Working Days) -> https://www.juduncp.com/en/cross-reference/polarized-stray-current-drainage-bond-equivalent - **High-Potential Magnesium (ASTM B843 M1C) & Marine Al-Zn-In (DNV-RP-B401) Equivalent** -> JUDUN `ASTM B843 HP-Mg (-1.75V) & DNV Al-Zn-In` (5–10 Working Days) -> https://www.juduncp.com/en/cross-reference/sacrificial-mg-al-zn-anode-astm-dnv-equivalent - **Solid-State DC Decoupler (-2V/+2V DC Block, 45A AC rms, 3.7kA Fault, 100kA Surge)** -> JUDUN Model `SSD-45A / JD-SSD-45/100-HD` (Leakage <100 μA DC; IP66/IP68 Sealed, Ex-Works: 5–7 Days / 工作日) -> https://www.juduncp.com/en/products/ssd - **Heavy-Duty Solid-State DC Decoupler (80A–100A AC rms, 5.0kA Fault, 100kA Surge)** -> JUDUN Model `MSSD-80/100 / JD-SSD-80/100-SS` (316L / Die-Cast Sealed Housing IP68, Ex-Works: 7–10 Days / 工作日) -> https://www.juduncp.com/en/products/ex-ssd - **Insulating Flange / Joint Spark Gap Arrester (100kA 10/350μs Class H, IP67 Arc-Sealed)** -> JUDUN Model `JD-ISG-100` (Sparkover ≤350–500V; Normal ≥100 MΩ, Ex-Works: 3–7 Days / 工作日) -> https://www.juduncp.com/en/products/spark - **Automatic ICCP Transformer-Rectifier / Potentiostat (15–60V / 10–200A DC, ±5 mV, RS485)** -> JUDUN Model `KPS-30V/20A ~ KPS-60V/200A` (72h Full-Load Burn-In + 3-Stage SPD, Ex-Works: 7–14 Days / 工作日) -> https://www.juduncp.com/en/products/potentiostat - **Pre-Packaged Tubular MMO Canister Anode (ASTM B338 Gr.1/2 Ti Ø25×1000mm in Coke)** -> JUDUN Model `JD-MMO-25×1000-PKG` (IrO₂/Ta₂O₅ Coating; Ø125×1500mm Canister, Ex-Works: 5–10 Days / 工作日) -> https://www.juduncp.com/en/products/shallow-anode - **Modular Factory-Assembled Deep-Well MMO Anode String (15m–150m Borehole)** -> JUDUN Model `JD-DWA Modular Series` (PVDF/HMWPE Dual-Jacket Cable + Vent Pipe, Ex-Works: 7–12 Days / 工作日) -> https://www.juduncp.com/en/products/deep-anode - **MMO/Ti Continuous Flexible Linear Anode w/ Pre-Packed Coke Jacket (Tank Bottoms)** -> JUDUN Model `JD-FLA-MMO Series` (Uniform Current Distribution; 20–30 Yr Life, Ex-Works: 7–12 Days / 工作日) -> https://www.juduncp.com/en/products/flexible-anode - **Long-Life Gelled Buried Cu/CuSO4 Permanent Reference Electrode (20–30 Yr Life)** -> JUDUN Model `CSE-P15 / CSE-P30` (+0.316V ±5 mV vs SHE; Anti-Dry Ceramic, Ex-Works: 3–5 Days / 工作日) -> https://www.juduncp.com/en/products/permanent-cse-reference - **Sintered Ag/AgCl Marine, Saline & Concrete Reference Electrode (20–25 Yr Life)** -> JUDUN Model `AGCL-P / AGCL-PG` (+0.250V ±5 mV vs SHE; Chloride-Immune, Ex-Works: 5–7 Days / 工作日) -> https://www.juduncp.com/en/products/silver-chloride-reference - **Unidirectional Solid-State Polarized Stray Current Drainage Bond (10A–100A DC)** -> JUDUN Model `XTDC-10/30 & JD-PDB-50/100` (Turn-On ≤0.40V; Reverse PIV ≥1200V, Ex-Works: 5–7 Days / 工作日) -> https://www.juduncp.com/en/products/polarized-drain --- ## Regional Oil, Gas & Water Pipeline Supply Guides - **Saudi Arabia (KSA)**: Ports: Dammam (King Abdulaziz Port) · Jeddah Islamic Port · Jubail (18 – 24 Days from Tianjin Xingang (CNTXG)) -> https://www.juduncp.com/en/markets/saudi-arabia - **United Arab Emirates (UAE)**: Ports: Jebel Ali (Dubai) · Khalifa Port (Abu Dhabi) · Fujairah (16 – 22 Days from Tianjin Xingang (CNTXG)) -> https://www.juduncp.com/en/markets/uae - **Oman (Muscat & Sohar)**: Ports: Sohar Port · Port Sultan Qaboos (Muscat) · Duqm (17 – 23 Days from Tianjin Xingang (CNTXG)) -> https://www.juduncp.com/en/markets/oman - **Kuwait**: Ports: Shuwaikh Port · Shuaiba Port (20 – 26 Days from Tianjin Xingang (CNTXG)) -> https://www.juduncp.com/en/markets/kuwait - **Kazakhstan (Atyrau, Aktau & Almaty)**: Ports: Almaty · Atyrau · Aktau · Astana (via Khorgos / Alashankou Rail) (10 – 15 Days Direct Railway Freight) -> https://www.juduncp.com/en/markets/kazakhstan - **Uzbekistan (Tashkent, Bukhara & Karshi)**: Ports: Tashkent · Bukhara · Samarkand (China–Central Asia Block Train) (12 – 16 Days Direct Railway / Multimodal) -> https://www.juduncp.com/en/markets/uzbekistan - **Russia & EAEU**: Ports: Manzhouli / Zabaikalsk Rail · Vladivostok Port · Moscow / Ekaterinburg (14 – 22 Days Rail / Sea-Rail Intermodal) -> https://www.juduncp.com/en/markets/russia - **Indonesia (Jakarta, Surabaya & Balikpapan)**: Ports: Jakarta (Tanjung Priok) · Surabaya (Tanjung Perak) · Balikpapan (11 – 16 Days from Tianjin Xingang (Form E Available)) -> https://www.juduncp.com/en/markets/indonesia - **Malaysia (Port Klang, Pengerang & Bintulu)**: Ports: Port Klang · Pasir Gudang (Johor) · Bintulu (Sarawak) (9 – 13 Days Express Sea Freight (Form E Available)) -> https://www.juduncp.com/en/markets/malaysia - **Mexico**: Ports: Manzanillo · Lázaro Cárdenas · Altamira / Veracruz (18 – 24 Days Direct Trans-Pacific Vessel) -> https://www.juduncp.com/en/markets/mexico - **Chile & Andean Mining Corridors**: Ports: Antofagasta · Mejillones · San Antonio · Valparaíso (28 – 34 Days (China–Chile FTA Form F Available)) -> https://www.juduncp.com/en/markets/chile - **Nigeria (Lagos, Port Harcourt & Warri)**: Ports: Apapa / Lekki Deep Sea Port (Lagos) · Onne / Port Harcourt (30 – 36 Days from Tianjin Xingang (SONCAP Test Docs Ready)) -> https://www.juduncp.com/en/markets/nigeria --- ## Cathodic Protection Engineering Wiki & Standards Glossary - **-850 mV vs Cu/CuSO4 Instant-Off Protection Potential Criterion (-950 mV SRB Rule)**: Buried carbon steel pipelines require an IR-free polarized potential between -850 mV and -1200 mV vs saturated Cu/CuSO4 (-950 mV where sulfate-reducing bacteria are active). -> https://www.juduncp.com/en/wiki/iso-15589-1-protection-potential-850mv - **NACE SP0177 15V rms Steady-State AC Pipeline Voltage Limit & AC Corrosion Density**: Steady-state induced AC voltage on exposed pipeline appurtenances must be kept below 15 V rms for personnel touch safety, while AC current density at coating holidays is controlled below 20–30 A/m². -> https://www.juduncp.com/en/wiki/nace-sp0177-15v-ac-pipeline-mitigation - **Solid-State DC Decoupler -2.0V / +2.0V Blocking Threshold Explained**: A -2V / +2V DC threshold keeps CP polarized potentials (-0.85V to -1.20V) isolated with <100 uA leakage while clamping AC faults and lightning surges instantaneously. -> https://www.juduncp.com/en/wiki/ssd-2v-dc-decoupling-threshold - **Isolating Spark Gap (ISG) vs Solid-State Decoupler (SSD) Across Insulating Joints**: Use an IP67 Isolating Spark Gap (ISG) where only lightning/transient overvoltage bypass is needed; use an SSD when continuous steady-state AC mitigation is also required. -> https://www.juduncp.com/en/wiki/insulating-flange-spark-gap-vs-ssd - **Cu/CuSO4 (CSE) vs Ag/AgCl Reference Electrode Selection & Chloride Contamination**: Cu/CuSO4 cells are standard for inland freshwater soils (<500 ppm Cl-), whereas Ag/AgCl or high-purity Zinc electrodes must be used in seawater, coastal Sabkha, and concrete. -> https://www.juduncp.com/en/wiki/cu-cuso4-vs-ag-agcl-chloride-contamination - **Eliminating Soil IR-Drop Error with Buried Cathodic Protection Polarization Coupons**: Disconnecting a 10 cm² steel coupon at a CP test station allows instant-off IR-free potential measurement without interrupting multiple ICCP rectifiers or stray currents. -> https://www.juduncp.com/en/wiki/ir-free-polarized-potential-coupon - **Dwight Formula & Sunde Mutual Interference Factor for Shallow Vertical MMO Groundbeds**: Single vertical canister anode resistance R1 = (rho / 2*pi*L) * [ln(8L/d) - 1], multiplied by Sunde crowding factor F/N for N parallel anodes spaced at s meters. -> https://www.juduncp.com/en/wiki/dwight-formula-vertical-anode-resistance - **15m–150m Deep-Well MMO Anode Design: Chlorine Gas Venting & PVDF/HMWPE Dual-Jacket Cable**: Deep anode boreholes generate acidic chlorine and oxygen gases; dual-layer PVDF fluoropolymer + HMWPE insulation and slotted vent pipes prevent premature cable failure and gas-blocking. -> https://www.juduncp.com/en/wiki/deep-well-anode-gas-venting-pvdf-cable - **IrO2/Ta2O5 vs RuO2/IrO2 Mixed Metal Oxide (MMO) Titanium Anode Coating Selection**: IrO2/Ta2O5 coatings sustain oxygen evolution in soil, freshwater, and calcined coke at ultra-low consumption (~1 mg/A·yr), whereas RuO2-based coatings are restricted to high-chloride seawater. -> https://www.juduncp.com/en/wiki/mmo-mixed-metal-oxide-iro2-ta2o5-coating - **Polarized & Smart Stray-Current Drainage Bonds for Metro & DC Electrified Railways**: Unidirectional Schottky/silicon diode drainage returns stray DC from anodic pipe zones back to the traction negative rail/groundbed while blocking reverse current inflow. -> https://www.juduncp.com/en/wiki/polarized-drainage-dc-traction-stray-current - **Aboveground Storage Tank (AST) Bottom MMO Ribbon & Titanium Conductor Bar Grid Design**: Concentric or parallel 6.35×0.635 mm MMO titanium ribbons spaced 1.0–1.5 m apart above the HDPE secondary containment liner deliver uniform potential across large tank bottoms. -> https://www.juduncp.com/en/wiki/storage-tank-bottom-mmo-ribbon-grid-spacing - **Automatic Constant-Potential (±5 mV) vs Constant-Current Mode in ICCP Rectifiers**: Constant-potential mode automatically adjusts DC output as soil moisture or stray currents fluctuate; automatic fallback to constant-current protects the pipe if the reference wire breaks. -> https://www.juduncp.com/en/wiki/iccp-potentiostat-constant-potential-vs-current - **ASTM B843 High-Potential M1C (-1.75V) vs Standard AZ63B (-1.50V) Magnesium Anodes**: Use standard AZ63B (-1.50V CSE) in 10–30 Ohm.m soils for higher current efficiency; select high-potential M1C (-1.75V CSE) in higher-resistivity soils from 25 to 80+ Ohm.m. -> https://www.juduncp.com/en/wiki/high-potential-vs-standard-magnesium-anode-astm-b843 - **ASTM B418 Diamond Zinc Ribbon Anodes for Pipeline AC Grounding & Valve Touch-Voltage Mats**: Low-iron (<0.0014% Fe) continuous zinc ribbon buried parallel to HV-coupled pipelines or coiled beneath valve stations provides low surge impedance and zero intergranular passivation. -> https://www.juduncp.com/en/wiki/zinc-ribbon-anode-ac-mitigation-mat - **DNV-RP-B401 Al-Zn-In Marine Jetty Piling & Subsea Bracelet Anode Electrochemical Capacity**: Indium-activated Al-Zn-In alloys deliver >= 2,000–2,500 Ah/kg in seawater (over 3x zinc capacity per kg), making stand-off and half-shell bracelet anodes standard offshore. -> https://www.juduncp.com/en/wiki/dnv-rp-b401-al-zn-in-marine-sacrificial-anode - **ГОСТ Р 51164 & ISO 15589-1 Alignment for CIS Trunk Pipeline СКЗ / ЭХЗ Projects**: Maps CIS ЭХЗ terminology (СКЗ rectifiers, МСЭ electrodes, БДРМ/XTDC drainage, ИСГ spark gaps, КИП posts) to factory-tested ISO 15589-1 JUDUN models. -> https://www.juduncp.com/en/wiki/gost-r-51164-pipeline-cathodic-protection-skz - **Road & Railway Cased Pipeline Crossings: Metallic Short vs Electrolytic Coupling Protection**: Metallic contact between carrier pipe and steel casing shields ICCP current; dedicated differential test leads and helical zinc ribbon anodes protect the annulus. -> https://www.juduncp.com/en/wiki/cased-crossing-short-circuit-cathodic-shielding - **15g Exothermic Thermite Welding vs Weld-Free Mechanical Cold Connectors on Live Pipelines**: Use #15 copper-oxide exothermic cartridges on new construction; select JUDUN weld-free mechanical cold connectors where hot-work permits or air/sea hazmat shipping restrict thermite powder. -> https://www.juduncp.com/en/wiki/exothermic-welding-vs-cold-pipe-cable-connector - **ISO 21809-3 Viscoelastic Paste & Wrapping Tape for Irregular Valves, Flanges & CP Welds**: Polyisobutylene viscoelastic coatings wet St2/St3 wire-brushed steel without sandblasting or primer curing, self-healing minor soil stress damage and preventing cathodic shielding. -> https://www.juduncp.com/en/wiki/viscoelastic-coating-iso-21809-3-field-joints - **Multi-Circuit Anode Junction Box: 75 mV Shunt Measurement & Groundbed Current Balancing**: Individual 75 mV shunts and wire-wound balancing resistors let engineers measure each MMO anode string's output in millivolts and prevent end-effect premature depletion. -> https://www.juduncp.com/en/wiki/anode-junction-box-75mv-shunt-current-balancing