Complete package delivery of dual-channel potentiostats, MMO linear anodes, Ex anode junction boxes, dual CSE/Zinc permanent references, and center-bottom access tubes.
Project Scope
Four newly constructed 50,000 m³ (Ø60 m) floating-roof crude oil storage tanks at a coastal terminal incorporated secondary containment HDPE liners beneath the sand pad—preventing conventional perimeter groundbeds from reaching the tank floor undersides.
JUDUN Turnkey Supply
- Power & Distribution: Four
KPS-30V/30Aautomatic potentiostats paired with 316L stainlessExmulti-circuit anode junction boxes; - Anode Grid: Concentric rings of MMO/Ti Linear Flexible Anodes installed within the sand pad between the HDPE liner and steel tank floor (30-year design life);
- Redundant Sensing: Four pairs of Permanent CSE + High-Purity Zinc Reference Electrodes per tank plus a radial DN65 Reference Electrode Access Tube reaching the tank center for periodic calibration.
Commissioning Outcome
Hydrotest and commissioning surveys verified uniform current distribution across the full Ø60 m floor, with center-to-rim potential spread under 95 mV and instant-off potentials held steadily within -0.92V to -1.06V vs. CSE.