✉ sales@juduncp.com ☎ +86 153 0327 5365 / +86-317-6220889 ISO 9001 · ISO 14001 · ISO 45001 Certified | 12 Patents & Software Copyrights
معدات الاختبار والمراقبة

Cathodic Protection Potential Data Logger

المعايير المعتمدة: NACE TM0497, ISO 15589-1, SY/T 0023, GB/T 21246

Ultra-low-power 4G / LTE Cat-M1 / NB-IoT wireless telemetry logger that fits directly inside standard or explosion-proof CP test posts to measure ON/OFF potentials, AC voltage, and coupon currents.

Typical Field Applications: Pipeline right-of-way test stations, IR-free instant-off potential monitoring, tank bottom & marine reference sensing

المواصفات الفنية

Measurement ChannelsON/OFF DC Potential (-5V~+5V), AC Voltage (0~100V), AC/DC Coupon Current
Battery & Ex Rating≥ 5 Years battery life; Intrinsic safety Ex ib IIC T4 Gb, IP68
Connectivity4G LTE / NB-IoT / MQTT / Modbus TCP open API

جدول الطرازات والأبعاد القياسية

Model Number Key Rating Dimensions & Configuration
JD-DL-4G-IP68 5-Channel Wireless CP Telemetry Unit Compact Cylinder Ø76 × 220 mm (Fits Ø108 Test Post)
JD-DL-Ex-IIC Intrinsically Safe Ex ib IIC T4 Logger Cast Aluminum IP68 Sealed Module + External Antenna

منتجات ذات صلة

Cathodic Protection Test Station
معدات الاختبار والمراقبة

Cathodic Protection Test Station

Right-of-way pipeline monitoring post for potential measurement, sacrificial anode current testing, casing isolation checks, and coupon connections. Available in 304/316L stainless steel, coated carbon steel, or UV-stabilized FRP.

Specs
Explosion-Proof CP Test Station
معدات الاختبار والمراقبة

Explosion-Proof CP Test Station

Hazardous-location cathodic protection test station featuring an Ex d IIB/IIC T6 flameproof terminal head for refineries, gas compressor stations, tank farms, and LNG terminals.

Specs
Permanent Reference Electrode
معدات الاختبار والمراقبة

Permanent Reference Electrode

Buried long-life electrochemical reference sensor providing drift-free potential feedback for automatic ICCP transformer-rectifiers and remote monitoring data loggers.

Specs
Permanent Copper/Copper Sulfate Reference Electrode (CSE)
معدات الاختبار والمراقبة

Permanent Copper/Copper Sulfate Reference Electrode (CSE)

Controlled-porosity ceramic membrane with gelled saturated CuSO₄ electrolyte and moisture-retentive backfill, engineered to resist drying out in onshore soil and tank-bottom service.