Guía de Diagnóstico de Fallas en Protección Catódica y Repuestos Urgentes

Identifique causas de alto voltaje/baja corriente en rectificadores, juntas aislantes en corto, voltajes AC >15V y deriva de celdas Cu/CuSO4 con despacho rápido de fábrica.

FAULT-01

ICCP Rectifier Output Voltage at Maximum Limit, But DC Current Drops Near Zero

Causa Raíz Probable

High loop resistance in the auxiliary anode circuit: depleted/passivated anodes, dried-out coke column, chlorine gas-blocking in a deep-well borehole, or severed positive (+) header cable.

Verificación en Campo con Multímetro

1) Measure DC voltage across (+) and (-) terminals at the rectifier cabinet; 2) Open the Anode Junction Box and measure millivolt drop across each 75 mV shunt to isolate dead strings; 3) Measure anode-to-remote-earth resistance against baseline commissioning records.

FAULT-02

Rectifier Running at Full Rated Current Limit, Yet Pipe Potential Remains Less Negative Than -850 mV

Causa Raíz Probable

Severe current drain ('parasitic short'): shorted station insulating flange, metallic contact between carrier pipe and road-crossing steel casing, or bare station copper earthing grid bonded directly without a DC decoupler.

Verificación en Campo con Multímetro

1) Compare ON/OFF pipe-to-soil potentials on both sides of station insulating joints; 2) Check pipe-to-casing potential difference (< 50 mV indicates likely metallic contact); 3) Clamp-meter DC current along station earthing bonds.

FAULT-03

Zero Potential Difference Across Insulating Flange / Monolithic Joint After Thunderstorm

Causa Raíz Probable

Lightning overvoltage flashover carbonized the insulating flange gasket, or an older open-type surge arrester failed in short-circuit mode.

Verificación en Campo con Multímetro

1)Temporarily unbolt one lead of the existing surge device across the flange; 2) If pipe potential immediately recovers (-950 mV vs -550 mV), only the surge device is shorted—replace with an IP67 100kA JD-ISG-100; 3) Check flange bolt sleeve insulation.

FAULT-04

Steady-State Induced AC Voltage Above 15 V rms at Test Posts & Valve Risers

Causa Raíz Probable

Electromagnetic inductive coupling from parallel 110 kV–500 kV overhead powerlines without low-impedance AC decoupling groundbeds.

Verificación en Campo con Multímetro

1) Switch multimeter to AC Volts and log 24h peak induced AC vs soil; 2) Measure AC current density on a 1 cm² coupon (> 30 A/m² indicates active AC corrosion risk per NACE SP0177); 3) Bond pipe through 45A–100A SSD units to continuous zinc ribbon.

FAULT-05

Erratic Control Potential or Coating Over-Protection (<-1.35V) on Automatic Potentiostat

Causa Raíz Probable

Buried permanent Cu/CuSO4 reference electrode dried out, froze, or suffered chloride ion poisoning (>500 ppm Cl- in coastal/saline soil).

Verificación en Campo con Multímetro

1) Place a freshly calibrated portable Cu/CuSO4 electrode on moist soil directly above the pipe; 2) Compare portable reading against the buried permanent cell lead (> 20 mV discrepancy confirms cell drift); 3) Replace with gelled CSE-P30 (inland) or Ag/AgCl (saline/coastal).

FAULT-06

Rapid Positive/Negative Pipe Potential Swings (-0.3V to -2.2V) Near Metro or DC Rail

Causa Raíz Probable

Dynamic DC traction return leakage current entering and discharging from the pipeline during train acceleration cycles.

Verificación en Campo con Multímetro

1) Record synchronous pipe-to-soil and pipe-to-rail voltage over peak transit hours using a 4G data collector; 2) Identify anodic discharge zones (pipe positive relative to rail/groundbed); 3) Install unidirectional Polarized or Smart Drainage Station.

FAULT-07

End Canisters in Shallow Groundbed Deplete Prematurely Within 3–5 Years

Causa Raíz Probable

Current crowding ('end effect') and localized low-resistivity pockets without per-string balancing resistors.

Verificación en Campo con Multímetro

1) Route individual anode tail leads into an SS316L Multi-Channel Anode Junction Box; 2) Read each 75 mV shunt; 3) Adjust wire-wound ceramic resistors to equalize current within +/- 10% across all canisters.

FAULT-08

Broken CP Test / Drain Cable on Live Pressurized Gas Pipeline Where Hot-Work Welding is Banned

Causa Raíz Probable

Excavation damage or soil settlement sheared the cable lug on an operating hydrocarbon line where open-flame thermite ignition is prohibited.

Verificación en Campo con Multímetro

1) Wire-brush a 50×50 mm spot to St3 bright metal; 2) Attach cable using a JUDUN Weld-Free Mechanical Cold Pipe Connector (< 1 mOhm contact resistance, zero spark); 3) Encapsulate completely with ISO 21809-3 Viscoelastic Paste & Tape.