Impressed Current (ICCP) vs. Sacrificial Anode Cathodic Protection: Engineering Sizing Guide

Guias Técnicos
Impressed Current (ICCP) vs. Sacrificial Anode Cathodic Protection: Engineering Sizing Guide

Based on ISO 15589-1 and NACE SP0169, compare ICCP and galvanic anode systems across soil resistivity, coating quality, power availability, and 25-year lifecycle cost.

Choosing between Impressed Current Cathodic Protection (ICCP) and Sacrificial (Galvanic) Anodes depends on asset geometry, coating breakdown factor, soil resistivity, and AC power availability:

When to Specify ICCP

  • Long-distance transmission pipelines where a single transformer-rectifier station protects 20–50+ km of well-coated pipe;
  • Large aboveground storage tank (AST) farms utilizing concentric MMO ribbon/flexible anodes or deep-well groundbeds;
  • Medium-to-high resistivity soils (> 100 Ω·m) requiring adjustable driving voltages (15V–60V DC) and high current capacity (10A–200A).

When to Specify Sacrificial Anodes

  • Urban distribution piping, short isolated laterals, cased road crossings, and remote sites lacking grid or solar power;
  • Congested underground corridors where zero stray-current interference to foreign utilities is mandatory;
  • Tank internal bottom water zones and marine structures (low-resistivity electrolytes ideal for ASTM B418 zinc anodes).