Eliminating Soil IR-Drop Error Using Polarization Coupons, Probes & Wireless Loggers

Технические руководства
Eliminating Soil IR-Drop Error Using Polarization Coupons, Probes & Wireless Loggers

When multi-rectifier interruption is impractical, pipeline-matched polarization coupons and probes paired with 4G data loggers provide accurate IR-free instant-off potentials.

International standards (ISO 15589-1 and NACE SP0169) require cathodic protection compliance (-850 mV to -1200 mV vs. CSE) to be evaluated on an IR-free polarized potential basis. Relying solely on ON-potentials masks severe under-protection when soil resistivity or current density creates hundreds of millivolts of ohmic IR drop.

Where GPS-synchronized interruption of all rectifiers, galvanic anodes, and foreign bonds is impractical, installing a 10 cm² / 1 cm² Polarization Coupon or Luggin-Tip Polarization Probe wired to a JUDUN 4G Potential Data Logger solves the challenge: the logger's internal solid-state relay interrupts only the local coupon bond for milliseconds, capturing true instant-off potential and AC current density (A/m²) continuously.