Code Basis: ISO 15589-1 / NACE SP0169
المعيار الهندسي والتطبيق الميداني
Per ISO 15589-1:2015 Table 1 and AMPP/NACE SP0169, external corrosion of buried carbon steel is mitigated when the true polarized (instant-off) potential is at least -850 mV relative to a saturated copper/copper sulfate reference electrode (CSE) in aerated soils, or -950 mV vs CSE in anaerobic soils with sulfate-reducing bacteria (SRB). Simultaneously, polarized potentials should not be more negative than -1200 mV vs CSE on 3LPE/FBE coated pipelines to avoid cathodic disbondment and hydrogen embrittlement. Accurate verification requires permanent buried CSE cells placed within 150–300 mm of the pipe surface paired with IR-free polarization coupons and automatic constant-potential ICCP rectifiers.
معدات مصنع JUDUN المطابقة
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
NACE SP0177 15V rms Steady-State AC Pipeline Vol...Solid-State DC Decoupler -2.0V / +2.0V Blocking ...Isolating Spark Gap (ISG) vs Solid-State Decoupl...Cu/CuSO4 (CSE) vs Ag/AgCl Reference Electrode Se...Eliminating Soil IR-Drop Error with Buried Catho...Dwight Formula & Sunde Mutual Interference Facto...15m–150m Deep-Well MMO Anode Design: Chlorine Ga...IrO2/Ta2O5 vs RuO2/IrO2 Mixed Metal Oxide (MMO) ...Polarized & Smart Stray-Current Drainage Bonds f...