Нормативы: ISO 15589-1 / NACE SP0169
Инженерный критерий и практическое применение
Per ISO 15589-1:2015 Table 1 and AMPP/NACE SP0169, external corrosion of buried carbon steel is mitigated when the true polarized (instant-off) potential is at least -850 mV relative to a saturated copper/copper sulfate reference electrode (CSE) in aerated soils, or -950 mV vs CSE in anaerobic soils with sulfate-reducing bacteria (SRB). Simultaneously, polarized potentials should not be more negative than -1200 mV vs CSE on 3LPE/FBE coated pipelines to avoid cathodic disbondment and hydrogen embrittlement. Accurate verification requires permanent buried CSE cells placed within 150–300 mm of the pipe surface paired with IR-free polarization coupons and automatic constant-potential ICCP rectifiers.
Соответствующее заводское оборудование JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
Норматив NACE SP0177: предел наведенного перемен...Принцип работы порога блокировки -2В / +2В в тве...Искровой разрядник (ИСГ) или устройство развязки...Выбор электродов сравнения: медно-сульфатный (МС...Измерение поляризационного потенциала без омичес...Формула Дуайта (Dwight) и коэффициент взаимного ...Глубинные анодные заземлители MMO (15–150 м): га...Сравнение покрытий титановых анодов MMO: иридий-...Поляризованный и интеллектуальный дренаж блуждаю...