✅ Проверено инженерным отделом ЭХЗ JUDUN: Заводской контроль качества ISO 9001:2015 · Протокол 72ч испытаний
Нормативы: AC/DC Decoupling
Инженерный критерий и практическое применение
Normal impressed-current or sacrificial cathodic protection maintains a pipeline-to-earth DC voltage between -0.85 V and -1.50 V (or up to -1.75 V near high-potential magnesium anodes). By setting the solid-state decoupler DC blocking window to -2.0 V / +2.0 V, the device exhibits high DC impedance (leakage current below 100 microamperes) throughout normal CP operation, preventing loss of protection current into station grounding grids. Meanwhile, low-impedance capacitive/thyristor paths pass 50/60 Hz induced AC continuously (45A–100A rms) and clamp 3.7–5.0 kA AC fault currents and 100 kA (8/20 us) lightning surges safely to earth.
Соответствующее заводское оборудование JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
Критерий защитного потенциала -850 мВ (МСЭ) и -9...Норматив NACE SP0177: предел наведенного перемен...Искровой разрядник (ИСГ) или устройство развязки...Выбор электродов сравнения: медно-сульфатный (МС...Измерение поляризационного потенциала без омичес...Формула Дуайта (Dwight) и коэффициент взаимного ...Глубинные анодные заземлители MMO (15–150 м): га...Сравнение покрытий титановых анодов MMO: иридий-...Поляризованный и интеллектуальный дренаж блуждаю...