✅ Проверено инженерным отделом ЭХЗ JUDUN: Заводской контроль качества ISO 9001:2015 · Протокол 72ч испытаний
Нормативы: Reference Electrodes
Инженерный критерий и практическое применение
Copper/copper sulfate (Cu/CuSO4, +0.316 V vs SHE) permanent reference electrodes deliver 20–30 year stability in inland soils and freshwater sand pads. However, when chloride concentration exceeds ~500–1,000 ppm (such as seawater, coastal Sabkha flats in the Persian Gulf, or de-icing salt zones), chloride ions penetrate porous plugs and convert CuSO4 electrolyte, shifting reference potential unpredictably ('chloride poisoning') and causing ICCP potentiostats to under- or over-protect the pipe. In marine, brackish, hypersaline, and reinforced-concrete structures, sintered Silver/Silver Chloride (Ag/AgCl) or 99.995% High-Purity Zinc reference electrodes are mandatory.
Соответствующее заводское оборудование JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
Критерий защитного потенциала -850 мВ (МСЭ) и -9...Норматив NACE SP0177: предел наведенного перемен...Принцип работы порога блокировки -2В / +2В в тве...Искровой разрядник (ИСГ) или устройство развязки...Измерение поляризационного потенциала без омичес...Формула Дуайта (Dwight) и коэффициент взаимного ...Глубинные анодные заземлители MMO (15–150 м): га...Сравнение покрытий титановых анодов MMO: иридий-...Поляризованный и интеллектуальный дренаж блуждаю...