✅ Проверено инженерным отделом ЭХЗ JUDUN: Заводской контроль качества ISO 9001:2015 · Протокол 72ч испытаний
Нормативы: AMPP / NACE SP0177
Инженерный критерий и практическое применение
When welded steel pipelines share right-of-way corridors with 110 kV–500 kV overhead AC transmission lines, inductive coupling generates steady-state AC voltages during normal load and kilovolt spikes during phase-to-ground faults. NACE SP0177 specifies a maximum 15 V rms touch-potential threshold at above-ground valves and test stations, and ISO 18086 / EN 15280 requires limiting AC current density on a 1 cm² holiday coupon below 30 A/m² to prevent rapid AC pitting corrosion. Direct grounding drains away cathodic protection DC current; therefore, engineers bond the pipeline to zinc ribbon grounding beds through Solid-State DC Decouplers (SSD) that conduct 45A–100A steady AC while blocking CP DC within -2V/+2V.
Соответствующее заводское оборудование JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
Критерий защитного потенциала -850 мВ (МСЭ) и -9...Принцип работы порога блокировки -2В / +2В в тве...Искровой разрядник (ИСГ) или устройство развязки...Выбор электродов сравнения: медно-сульфатный (МС...Измерение поляризационного потенциала без омичес...Формула Дуайта (Dwight) и коэффициент взаимного ...Глубинные анодные заземлители MMO (15–150 м): га...Сравнение покрытий титановых анодов MMO: иридий-...Поляризованный и интеллектуальный дренаж блуждаю...