Reference Electrode & CP Test Station Selection Table: Permanent Cu/CuSO4 vs. Ag/AgCl vs. High-Purity Zn vs. Portable Half-Cell

Static reference lookup table of standard half-cell potentials vs. SHE, chloride limits, design life, and 2/4/6-wire CP Test Station terminal configurations per NACE TM0497.

1. Permanent & Portable Reference Electrode Potential Conversion & Selection Table

Electrode Type & JUDUN ModelStandard Potential (vs SHE, 25°C)Equivalent Steel Protection CriterionTarget EnvironmentAvoid InDesign Service Life
Permanent Gelled Cu/CuSO4 (CSE-P15 / CSE-P30)+0.316 V (±5 mV)-0.850 V to -1.200 VOnshore Chloride-Free Soils & Tank Sand PadsSeawater & Sabkha (>500 ppm Cl⁻)20 – 30 Years
Permanent Sintered Ag/AgCl (AGCL-P / AGCL-PG)+0.250 V (±5 mV)-0.800 V to -1.050 VSeawater, Saline Muds & Reinforced ConcreteDry Non-Conductive Rock Without Gel20 – 25 Years
Permanent High-Purity Zinc (ZRE-Soil / Marine)-0.780 V vs SHE (-1.10V vs CSE)+0.250 V vs Zn (≤ +0.25V)Permafrost, Under-Tank Redundant Pair & SubseaHot Alkaline Chemical Spills≥ 30 Years
Portable Cu/CuSO4 Half-Cell & CIPS Cane (JD-CSE-Port)+0.316 V (Pair diff ≤2 mV)-0.850 V Instant-OffTest-Post Audits, CIPS & DCVG Walking SurveysUnshaded Direct UV Without SleeveField Refillable

🌐 International Tender Designations & Regional Field Terminology

Permanent Buried Cu/CuSO4 Reference Electrode (CSE) · Long-Life Copper/Copper Sulfate Reference Cell (US) · Permanent Copper/Copper Sulphate Half-Cell (UK/GCC)
Permanent Silver/Silver Chloride Reference Electrode (Ag/AgCl) · Sintered Seawater & Sabkha Soil Reference Cell
Field & Survey EssentialPortable Reference Electrode
Portable Copper/Copper Sulfate Reference Electrode — Portable CSE (US) · Portable Copper/Copper Sulphate Half-Cell (UK / Commonwealth / GCC) · CIPS / DCVG Pipeline Survey Cane / Walking-Stick Electrode · Field-Refillable Porous Ceramic Tip Cu/CuSO4 Half-Cell
Field & Survey EssentialCathodic Protection Test Station
Cathodic Protection Test Station — CTS / ETS (US & NACE) · Pipeline Potential Monitoring Test Post (UK / Middle East) · Above-Ground CP Terminal Box / Test Point · 304/316L Stainless Steel & UV-FRP CP Marker Post

Engineering Sizing & Tender FAQs

How can engineers size equipment and prepare tender submittals for Reference Electrode & CP Test Station Selection Table: Permanent Cu/CuSO4 vs. Ag/AgCl vs. High-Purity Zn vs. Portable Half-Cell?

Corrosion engineers can verify protection current demand and groundbed resistance directly in JUDUN's online ISO 15589-1 Sizing Calculator (/en/calculator), download CAD installation details, and request factory submittal datasheets for Permanent Cu/CuSO4 Reference Electrode (Long-Life Buried CSE), Silver/Silver Chloride Reference Electrode (Ag/AgCl), Permanent High-Purity Zinc Reference Electrode with 24-hour quotation turnaround.

What QA/QC documentation and factory inspection (ITP) records accompany JUDUN export shipments?

Cangzhou Judun Pipeline Protection Equipment Co., Ltd. (ISO 9001, ISO 14001, and ISO 45001 certified) supplies Vendor Pre-Qualification (PQQ) dossiers, Factory Inspection & Test Plans (ITP), 72-hour full-load rectifier burn-in logs, EN 10204 3.1 material certificates, and supports TPI witness inspection (SGS, BV, TÜV).

Need Project-Specific CP Sizing or Turnkey EPC Submittal Files?

Run free ISO 15589-1 / Dwight calculations online, configure a complete project BoQ in 60 seconds, or download CAD installation details & Factory ITP dossiers.

Referenced Standards & Criteria Glossary

Related Cathodic Protection Engineering Guides

💬 WhatsApp