✉ sales@juduncp.com ☎ +86 153 0327 5365 / +86-317-6220889 ISO 9001 · ISO 14001 · ISO 45001 Certified | 12 Patents & Software Copyrights
← Back to News (Guides Techniques)

Reference Electrode & CP Test Station Selection Table: Permanent Cu/CuSO4 vs. Ag/AgCl vs. High-Purity Zn vs. Portable Half-Cell

Guides Techniques
✅ Technical Review: JUDUN Corrosion & CP Engineering Dept. (ISO 9001:2015 Certified · 72h Burn-In Verified)
Code Basis: ISO 15589-1:2015 / AMPP NACE SP0169
Reference Electrode & CP Test Station Selection Table: Permanent Cu/CuSO4 vs. Ag/AgCl vs. High-Purity Zn vs. Portable Half-Cell

Static reference lookup table of standard half-cell potentials vs. SHE, chloride limits, design life, and 2/4/6-wire CP Test Station terminal configurations per NACE TM0497.

1. Permanent & Portable Reference Electrode Potential Conversion & Selection Table

Electrode Type & JUDUN ModelStandard Potential (vs SHE, 25°C)Equivalent Steel Protection CriterionTarget EnvironmentAvoid InDesign Service Life
Permanent Gelled Cu/CuSO4 (CSE-P15 / CSE-P30)+0.316 V (±5 mV)-0.850 V to -1.200 VOnshore Chloride-Free Soils & Tank Sand PadsSeawater & Sabkha (>500 ppm Cl⁻)20 – 30 Years
Permanent Sintered Ag/AgCl (AGCL-P / AGCL-PG)+0.250 V (±5 mV)-0.800 V to -1.050 VSeawater, Saline Muds & Reinforced ConcreteDry Non-Conductive Rock Without Gel20 – 25 Years
Permanent High-Purity Zinc (ZRE-Soil / Marine)-0.780 V vs SHE (-1.10V vs CSE)+0.250 V vs Zn (≤ +0.25V)Permafrost, Under-Tank Redundant Pair & SubseaHot Alkaline Chemical Spills≥ 30 Years
Portable Cu/CuSO4 Half-Cell & CIPS Cane (JD-CSE-Port)+0.316 V (Pair diff ≤2 mV)-0.850 V Instant-OffTest-Post Audits, CIPS & DCVG Walking SurveysUnshaded Direct UV Without SleeveField Refillable

🌐 Dénominations Techniques d'Appels d'Offres Internationaux (NF EN / ISO / NACE)

Électrode de Référence Permanente Enterrée Cuivre/Sulfate de Cuivre (Cu/CuSO4)
Électrode de Référence Permanente Argent/Chlorure d'Argent (Ag/AgCl)
Essentiel de Terrain et MesurePortable Reference Electrode
Électrode de Référence Portable Cuivre/Sulfate de Cuivre (Demi-pile Cu/CuSO4) · Canne de Mesure CIPS / DCVG au Sulfate de Cuivre
Essentiel de Terrain et MesureCathodic Protection Test Station
Prise de Potentiel — Borne de Mesure de Protection Cathodique · Coffret de Mesure Cathodique sur Poteau

Questions Fréquentes d'Ingénierie et d'Appel d'Offres

How can engineers size equipment and prepare tender submittals for Reference Electrode & CP Test Station Selection Table: Permanent Cu/CuSO4 vs. Ag/AgCl vs. High-Purity Zn vs. Portable Half-Cell?

Corrosion engineers can verify protection current demand and groundbed resistance directly in JUDUN's online ISO 15589-1 Sizing Calculator (/fr/calculator), download CAD installation details, and request factory submittal datasheets for Électrode de Référence Permanente Cu/CuSO4 Longue Durée (CSE), Électrode de Référence Permanente Argent/Chlorure d'Argent Ag/AgCl (Eau de Mer & Sols Salins), Permanent High-Purity Zinc Reference Electrode with 24-hour quotation turnaround.

What QA/QC documentation and factory inspection (ITP) records accompany JUDUN export shipments?

Cangzhou Judun Pipeline Protection Equipment Co., Ltd. (ISO 9001, ISO 14001, and ISO 45001 certified) supplies Vendor Pre-Qualification (PQQ) dossiers, Factory Inspection & Test Plans (ITP), 72-hour full-load rectifier burn-in logs, EN 10204 3.1 material certificates, and supports TPI witness inspection (SGS, BV, TÜV).

Besoin d'un dimensionnement ISO 15589-1 ou d'un bordereau complet (BoQ / ITP) ?

Utilisez notre calculateur gratuit ISO 15589-1, configurez votre BoQ ou téléchargez les plans CAD et le dossier PQQ/ITP usine.

Normes Internationales Associées

Guides Techniques Connexes en Protection Cathodique

💬 WhatsApp