Impressed Current CP (ICCP)
Potentiostats / transformer-rectifiers, MMO tubular, deep-well & flexible linear anodes for transmission pipelines and tank farms.
Explore System Products →
Redresseurs, anodes MMO et sacrificielles, découpleurs à semi-conducteurs (SSD), électrodes de référence, postes de mesure et soudure exothermique pour canalisations.
Navigate equipment and field accessories by corrosion control mechanism for one-stop BoQ package sourcing.

Potentiostats / transformer-rectifiers, MMO tubular, deep-well & flexible linear anodes for transmission pipelines and tank farms.
Explore System Products →
High-potential & standard magnesium anodes, high-purity zinc anodes, and zinc ribbon requiring zero external power.
Explore System Products →
Solid-state decouplers (SSD / Ex-SSD), isolating spark gaps, smart drainage units, and zinc grounding cells for HV corridors.
Explore System Products →
Precision transformer-rectifier / potentiostat for impressed current cathodic protection (ICCP), featuring automatic potential/current control, surge protection, and RS485 Modbus telemetry.
Continuous linear MMO/Ti wire or conductive polymer flexible anode pre-packed with coke breeze fabric jacket for uniform current distribution on storage tank bottoms and congested station piping.
Available in High-Potential (M1C, -1.75V CSE) and Standard-Potential (AZ63B, -1.50V CSE) alloys, supplied bare or pre-packaged in gypsum-bentonite cotton bags with pre-welded lead wires.
Blocks cathodic protection DC current while providing a low-impedance path to ground for induced steady-state AC current, AC fault surges, and lightning transients.
Hazardous-area certified Ex d IIC T6 Gb flameproof solid-state decoupler engineered for Zone 1 & Zone 2 gas stations, valve chambers, tank farms, and above-ground insulating joints.
Right-of-way pipeline monitoring post for potential measurement, sacrificial anode current testing, casing isolation checks, and coupon connections. Available in 304/316L stainless steel, coated carbon steel, or UV-stabilized FRP.
High-stability sintered Ag/AgCl reference electrode built for seawater, brackish mud, high-chloride saline soils, and reinforced concrete structures where CSE electrodes suffer chloride contamination.
Ultra-low-power 4G / LTE Cat-M1 / NB-IoT wireless telemetry logger that fits directly inside standard or explosion-proof CP test posts to measure ON/OFF potentials, AC voltage, and coupon currents.
Located in China's pipeline equipment hub—consolidate power units, anodes, monitoring stations, and thermite welding consumables in one shipment.
Built and factory-tested in accordance with ISO 15589-1, NACE SP0169, ASTM B843 / B418, and IECEx/ATEX flameproof design practices.
Tailored ratings, 316L/FRP enclosures, pre-wired cable tails, and custom English/Russian/Arabic engraved tags per EPC project specs.



Operating from Cangzhou's pipeline equipment hub, JUDUN expands automated burn-in testing for ICCP rectifiers, surge testing for SSD decouplers, and fast-response export documentation.
Read Article →
Based on ISO 15589-1 and NACE SP0169, compare ICCP and galvanic anode systems across soil resistivity, coating quality, power availability, and 25-year lifecycle cost.
Read Article →
Selecting the wrong reference electrode chemistry causes potential drift and rectifier miscontrol. Compare soil CSE, chloride-resistant Ag/AgCl, and rugged pure-zinc electrodes.
Read Article →Send your Bill of Quantities (BoQ) or project datasheet requirements. Our engineers respond within 24 hours with model sizing and pricing.