✉ sales@juduncp.com ☎ +86 153 0327 5365 / +86-317-6220889 ISO 9001 · ISO 14001 · ISO 45001 Certified | 12 Patents & Software Copyrights
← Back to Products  /  Interference Mitigation & Surge Protection  /  Solid-State Decoupler (SSD)
Interference Mitigation & Surge Protection

Solid-State Decoupler (SSD)

Applicable Standards: NACE SP0177, ISO 18086, EN 50162, IEC 60079-1 (Ex), GB/T 50698

Blocks cathodic protection DC current while providing a low-impedance path to ground for induced steady-state AC current, AC fault surges, and lightning transients.

Typical Field Applications: HV power line shared corridors, AC/DC electrified railway stray current zones, and insulating joint lightning surge protection

Technical Specifications

DC Blocking Threshold-2.0 V / +2.0 V (Optional -3.0 V / +1.0 V)
Steady-State AC Current45 A / 60 A / 80 A / 100 A rms continuous
AC Fault Current (30 cyc)3.7 kA / 5.0 kA rms @ 30 cycles
Lightning Surge Rating100 kA crest (8/20 μs)
Enclosure ProtectionIP65 / IP68 Submersible & Weatherproof

Standard Models & Selection Table

Model Number Key Rating Dimensions & Configuration
SSD-50-100-B302015 50A AC / 100kA Surge / -2V~+2V 300 × 200 × 150 mm Stainless Enclosure
SSD-50-100-B403015 80A AC / 100kA Surge / -2V~+2V 400 × 300 × 150 mm Heavy Enclosure
MSSD-50/100 45A–50A AC / 100kA Compact Module Ø110 × 230 mm Test-Post Mountable

Related System Products

Zinc Ribbon Anode
Sacrificial Anodes

Zinc Ribbon Anode

Extruded diamond-profile high-purity zinc ribbon with centralized steel wire core (ASTM B418 Type II), widely deployed alongside solid-state decouplers for AC mitigation grounding mats and cased pipeline crossings.

Specs
Flameproof Solid-State Decoupler (Ex-SSD)
Interference Mitigation & Surge Protection

Flameproof Solid-State Decoupler (Ex-SSD)

Hazardous-area certified Ex d IIC T6 Gb flameproof solid-state decoupler engineered for Zone 1 & Zone 2 gas stations, valve chambers, tank farms, and above-ground insulating joints.

Specs
Isolating Spark Gap (ISG)
Interference Mitigation & Surge Protection

Isolating Spark Gap (ISG)

Installed across pipeline insulating joints/flanges to maintain open-circuit DC/AC isolation under normal operation while firing instantaneously during lightning or HV surge events.

Specs
Indirect Equipotential Bonding Device
Interference Mitigation & Surge Protection

Indirect Equipotential Bonding Device

Provides indirect equipotential bonding between cathodically protected piping and station earthing grids—isolated during normal operation and instantaneously clamped under overvoltage faults.

Specs