✅ Technical Review: JUDUN Corrosion & CP Engineering Dept. (ISO 9001:2015 Certified · 72h Burn-In Verified)
Code Basis: Groundbed Design
Criterio de Ingeniería y Aplicación en Campo
In impressed current groundbed sizing, H.B. Dwight's equation calculates the earth-to-remote resistance of a single vertical cylindrical anode including its low-resistivity calcined petroleum coke column (effective diameter d, active length L) in soil of resistivity rho (Ohm.m): R_single = (rho / (2 * pi * L)) * (ln(8 * L / d) - 1). When N canisters (e.g., OD 125 × 1500 mm pre-packaged MMO canisters) are connected in parallel along a header cable at spacing s (typically 3–5 m), current crowding increases resistance per Sunde's mutual interference factor. You can compute exact single/multi-anode resistance and rectifier voltage instantly in JUDUN's online ISO 15589-1 Calculator.
Equipos Equivalentes de Fábrica JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
-850 mV vs Cu/CuSO4 Instant-Off Protection Poten...NACE SP0177 15V rms Steady-State AC Pipeline Vol...Solid-State DC Decoupler -2.0V / +2.0V Blocking ...Isolating Spark Gap (ISG) vs Solid-State Decoupl...Cu/CuSO4 (CSE) vs Ag/AgCl Reference Electrode Se...Eliminating Soil IR-Drop Error with Buried Catho...15m–150m Deep-Well MMO Anode Design: Chlorine Ga...IrO2/Ta2O5 vs RuO2/IrO2 Mixed Metal Oxide (MMO) ...Polarized & Smart Stray-Current Drainage Bonds f...