✉ sales@juduncp.com ☎ +86 153 0327 5365 / +86-317-6220889 ISO 9001 · ISO 14001 · ISO 45001 Certified | 12 Patents & Software Copyrights
← All Cross-Reference Guides

ICCP Transformer-Rectifier Unit (TRU / Potentiostat 15–60V, 10–200A DC) Equivalent

JUDUN Model: KPS Air-Cooled / Oil-Immersed / Modular HF ⚡ Ex-Works: 7–14 Working Days
✅ Technical Review: JUDUN Corrosion & CP Engineering Dept. (ISO 9001:2015 Certified · 72h Burn-In Verified)
Code Basis: ISO 15589-1:2015 / AMPP NACE SP0169 / SP0177
📌 Quick Engineering Summary (ISO 15589-1 / AMPP Criteria)

An Automatic ICCP Transformer-Rectifier Unit (JUDUN KPS Series) converts single-phase or three-phase AC power into regulated 15V–60V / 10A–200A DC output, maintaining pipe-to-soil potential within ±5 mV of the -0.85V CSE setpoint with RS485 Modbus SCADA telemetry and 72-hour rated-load burn-in verification.

🔍 View Full Product Datasheet & Models ✉ Request 24h Equivalent Quote 📋 Upload Project BoQ Sheet

Side-by-Side Technical Specification & Lead-Time Comparison

Engineering Parameter Typical International Tender / Legacy Spec JUDUN Direct Factory Equivalent Factory QC / Standard Basis
Operating Modes / 运行控制模式 Constant Potential / Constant Current Auto Constant Potential (±5 mV) + Auto Constant Current (±1%) + IR-Free Interrupter Ready ✓ Dual Redundant Card Option
Cooling & Ambient / 冷却结构与耐温 Air-Cooled Indoor / Oil-Immersed Outdoor Indoor Cabinet (IP42/IP54) or Desert Outdoor Oil-Immersed (IP55/IP65 up to +55°C) ✓ Suited for Middle East & Permafrost
Input Supply Voltage / 交流输入制式 110V / 220V / 380V / 400V / 480V Custom Wound to Country Grid (50 Hz or 60 Hz, 1-Ph or 3-Ph) ✓ Galvanically Isolated Copper Transformer
SCADA & Surge Protection / 远传与防雷 RS485 Modbus + AC/DC SPD Isolated RS485 Modbus RTU + 4–20mA + 3-Stage AC Input / DC Output / Ref SPD ✓ 72h Full-Load Burn-In Report

Engineering Compliance Note: All third-party series designations are referenced strictly for functional specification cross-matching under ISO 15589-1 / AMPP standards. JUDUN supplies independently engineered equipment manufactured in Cangzhou, China under ISO 9001:2015 quality control.

Engineering Cross-Reference FAQ

Can JUDUN build outdoor oil-immersed transformer-rectifiers for +55°C desert pipeline stations?
Yes. We manufacture hermetically sealed mineral-oil-immersed outdoor TRUs with sun-shield canopies and 380V/400V/480V 50/60Hz custom primaries for Saudi Arabia, UAE, Oman, and North African desert ROW sites.
10 Direct Factory Model Cross-Reference & Equivalent Guides:
SSD-45A / JD-SSD-80/100-SSSSD-45A / JD-SSD-45/100-HDJD-ISG-100JD-MMO-25×1000-PKG / MMO RibbonJD-DWA Modular String (15m–150m)JD-FLA-MMO Coke-Jacketed Linear AnodeCSE-P30 (Cu/CuSO₄) & AGCL-P (Ag/AgCl)XTDC-30 / JD-PDB-100 & Smart DrainASTM B843 HP-Mg (-1.75V) & DNV Al-Zn-In
FOR EPC CONTRACTORS & CORROSION DESIGN ENGINEERS (PDF + .DOCX)

Download Editable EPC Tender Specification (.DOCX) & Typical CP Installation Drawings

Includes 4 CAD-style vector installation detail sheets (ICCP Shallow Groundbed, 15–150m Deep-Well MMO String, HV Corridor SSD + Insulating Flange Spark Gap, Test Station & IR-Free Coupon) plus a ready-to-edit Microsoft Word (.docx) Project Technical Specification.

Cangzhou Judun Pipeline Protection Equipment Co., Ltd.

Tel / WhatsApp / WeChat +86 153 0327 5365 / +86-317-6220889
Manufacturing Base Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China

Your project details are kept strictly confidential for engineering quotation only. View Inquiry Privacy Notice.

💬 WhatsApp