✉ sales@juduncp.com ☎ +86 153 0327 5365 / +86-317-6220889 ISO 9001 · ISO 14001 · ISO 45001 Certified | 12 Patents & Software Copyrights
Atténuation des Interférences et Parafoudres

Isolating Spark Gap (ISG)

Applicable Standards: NACE SP0177, ISO 18086, EN 50162, IEC 60079-1 (Ex), GB/T 50698

Installed across pipeline insulating joints/flanges to maintain open-circuit DC/AC isolation under normal operation while firing instantaneously during lightning or HV surge events.

Typical Field Applications: HV power line shared corridors, AC/DC electrified railway stray current zones, and insulating joint lightning surge protection

Spécifications Techniques

Impulse Current (10/350μs)50 kA / 100 kA (10/350 μs Class H)
Power-Frequency Sparkover≤ 250 V – 500 V
Ex & IP RatingEx d IIC T6 Gb, IP67 arc-encapsulated

Modèles Standards

Model Number Key Rating Dimensions & Configuration
JD-ISG-50Ex 50kA (10/350μs), Sparkover ≤ 350V M20 Bolt / Bracket Mount with Dual Lugs
JD-ISG-100Ex 100kA (10/350μs) Heavy Duty Insulating Joint Flange Mounting Kit Included

Related System Products

Zinc Ribbon Anode
Anodes Sacrificielles

Zinc Ribbon Anode

Extruded diamond-profile high-purity zinc ribbon with centralized steel wire core (ASTM B418 Type II), widely deployed alongside solid-state decouplers for AC mitigation grounding mats and cased pipeline crossings.

Specs
Solid-State Decoupler (SSD)
Atténuation des Interférences et Parafoudres

Solid-State Decoupler (SSD)

Blocks cathodic protection DC current while providing a low-impedance path to ground for induced steady-state AC current, AC fault surges, and lightning transients.

Specs
Flameproof Solid-State Decoupler (Ex-SSD)
Atténuation des Interférences et Parafoudres

Flameproof Solid-State Decoupler (Ex-SSD)

Hazardous-area certified Ex d IIC T6 Gb flameproof solid-state decoupler engineered for Zone 1 & Zone 2 gas stations, valve chambers, tank farms, and above-ground insulating joints.

Specs
Indirect Equipotential Bonding Device
Atténuation des Interférences et Parafoudres

Indirect Equipotential Bonding Device

Provides indirect equipotential bonding between cathodically protected piping and station earthing grids—isolated during normal operation and instantaneously clamped under overvoltage faults.