Static side-by-side engineering lookup table mapping operating environments, soil/water resistivities, governing ISO/NACE/ASTM/DNV standards, and matched JUDUN equipment series.
1. Master Cathodic Protection & AC/DC Mitigation Equipment Selection Matrix
The static engineering reference table below maps pipeline, storage tank, and marine operating conditions directly to governing international standards and matched JUDUN hardware configurations:
| Application / Electrolyte | Resistivity / Interference | Governing Standard | Recommended System & JUDUN Series | Key Verification Criterion |
|---|---|---|---|---|
| Onshore Trunk Pipeline (25–50 km/station) | 10 – 300 Ω·m Soil | ISO 15589-1 / NACE SP0169 | KPS Transformer-Rectifier + JD-MMO Shallow or JD-DWA Deep-Well Anode | -850 mV to -1200 mV vs CSE (IR-free instant-off) |
| Moderate-to-High ρ Buried Pipe / Casing | 40 – 100 Ω·m Soil | ASTM B843 (M1C Grade) | Pre-Packaged High-Potential Magnesium Anode (MG-14kg-P / MG-22kg-P, -1.75V) | ≥ 100 mV cathodic polarization shift |
| Low-Resistivity Damp Clay / Loam | 15 – 40 Ω·m Soil | ASTM B843 (AZ63B H-1) | Pre-Packaged Standard Magnesium Anode (-1.50V CSE in 75/20/5 backfill) | -850 mV CSE polarized without coating disbondment |
| PCCP Prestressed Concrete Water Main | 5 – 30 Ω·m Soil | NACE SP0100 / ASTM B418 II | Self-Limiting Diamond Zinc Ribbon Anode (-1.10V CSE ceiling) | ≥ 100 mV shift; never more negative than -1000 mV CSE |
| Shared 110kV–500kV HVAC Corridor | Steady AC > 15 V rms | NACE SP0177 / ISO 18086 | SSD-45A / MSSD-100 Solid-State DC Decoupler + Zinc Ribbon Mat | Steady touch < 15 V AC; 1 cm² coupon J_AC < 20 A/m² |
| Station Monolithic Isolating Joint | Lightning / Fault Surge | IEC 62561-3 Class H | JD-ISG-100 Sealed Isolating Spark Gap (100 kA 10/350μs, IP67) | Normal DC resistance ≥ 100 MΩ; impulse clamp < IJ breakdown |
| Metro / Electrified DC Rail Crossing | Dynamic Anodic Swing | EN 50162 / ISO 15589-1 | XTDC Polarized Drainage Bond (≤0.4V) or JD-SDR Smart Drainage Unit | Eliminate positive anodic excursion; reverse PIV ≥ 1200 V |
| AST Tank Bottom Above HDPE Liner | Washed Sand Cushion | API RP 651 | MMO Titanium Ribbon (6.35×0.635mm) + Ti Bar Grid + CSE-P30/Zn Dual Cell | Uniform -850 mV CSE across center & perimeter |
| Marine Jetty Piling & Subsea Pipe | Seawater 0.2–1.0 Ω·m | DNV-RP-B401 / ISO 15589-2 | Al-Zn-In Structural/Bracelet Anode (≥2400 Ah/kg) + Sintered Ag/AgCl Cell | -0.80 V to -1.05 V vs Ag/AgCl/seawater |
2. Right-of-Way Monitoring & Survey Equipment Pairing
Every transmission and distribution network above pairs permanent buried reference cells with 1 km interval CP Test Stations (Test Posts / КИП) in 304/316L stainless steel or UV-FRP, verified during annual CIPS/DCVG walks using calibrated Portable Cu/CuSO4 Half-Cells (±3 mV).
🌐 Принятые проектные наименования по стандартам СНГ (ГОСТ) и международным ТЗ
Частые инженерные вопросы по проектированию ЭХЗ
Как выполнить инженерный подбор оборудования ЭХЗ и получить спецификацию для тендера?
Инженеры могут воспользоваться бесплатным онлайн-калькулятором ЭХЗ по ISO 15589-1 (/ru/calculator) для расчета защитного тока и сопротивления анодного заземления, а также запросить заводские паспорта на Автоматическая станция катодной защиты СКЗ / Потенциостат KPS (15–60В, 10–200А, RS485), Твердотельный декуплирующий блок SSD (УЗНН 45А–100А, -2В/+2В, 100 кА), Стационарный медно-сульфатный электрод сравнения длительного действия МСЭ (Cu/CuSO4, 20–30 лет) с подготовкой КП в течение 24 часов.
Какие документы контроля качества (ITP / сертификаты) предоставляются при экспортной поставке?
Завод JUDUN (сертифицирован по ISO 9001, ISO 14001, ISO 45001) предоставляет полный пакет документации для EPC-подрядчиков: чертежи узлов монтажа CAD, план инспекций и испытаний (ITP), протоколы 72-часовых нагрузочных испытаний СКЗ и сертификаты материалов EN 10204 3.1.
Нужен расчет ЭХЗ по ISO 15589-1 или комплектация спецификации (BoQ)?
Используйте бесплатный онлайн-калькулятор ЭХЗ, соберите спецификацию BoQ или скачайте чертежи CAD и план контроля качества ITP.