✅ Проверено инженерным отделом ЭХЗ JUDUN: Заводской контроль качества ISO 9001:2015 · Протокол 72ч испытаний
Нормативы: Groundbed Commissioning
Инженерный критерий и практическое применение
In a 10- to 20-anode shallow groundbed or multi-zone storage tank ribbon grid, soil heterogeneity and end-effects cause individual anodes to discharge wildly unequal currents—exhausting end canisters years ahead of center anodes. Connecting each individual anode tail cable into a JUDUN SS304/SS316L Anode Junction Box equipped with calibrated manganin 75 mV shunts (e.g., 10A/75mV => 1 mV = 0.133 A) and adjustable ceramic wire-wound balancing resistors allows commissioning engineers to measure and equalize per-anode current without breaking the circuit.
Соответствующее заводское оборудование JUDUN
Cangzhou Judun Pipeline Protection Equipment Co., Ltd.
Email
sales@juduncp.com
Tel / WhatsApp / WeChat
+86 153 0327 5365 / +86-317-6220889
Manufacturing Base
Room 9-213, Bldg 09, Yanshan Int'l Business Center & Qiantong Industrial Zone, Cangzhou, Hebei, China
Критерий защитного потенциала -850 мВ (МСЭ) и -9...Норматив NACE SP0177: предел наведенного перемен...Принцип работы порога блокировки -2В / +2В в тве...Искровой разрядник (ИСГ) или устройство развязки...Выбор электродов сравнения: медно-сульфатный (МС...Измерение поляризационного потенциала без омичес...Формула Дуайта (Dwight) и коэффициент взаимного ...Глубинные анодные заземлители MMO (15–150 м): га...Сравнение покрытий титановых анодов MMO: иридий-...Поляризованный и интеллектуальный дренаж блуждаю...